{"product_id":"yokogawa-adv151-e63-digital-input-module","title":"Yokogawa ADV151-E63 Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-E63\u003c\/strong\u003e is a 32-channel isolated digital input module designed to receive 24 V DC ON\/OFF signals in the FIO (Fieldnetwork I\/O) architecture. It supports Sequence of Events (SOE) data capture, allowing discrete input transitions to be recorded for event analysis. The E63 configuration includes a status display and the ISA Standard G3 environmental option with an extended temperature range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-E63 acquires discrete field signals and transfers their ON\/OFF states to the control system. Its 32 input channels accept 24 V DC signals in either sink or source configurations.\u003c\/p\u003e\n\u003cp\u003eThe module supports three input functions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus input:\u003c\/strong\u003e Detects the ON\/OFF state of field signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSOE input:\u003c\/strong\u003e Captures Sequence of Events data for recording and analyzing discrete signal transitions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePushbutton input:\u003c\/strong\u003e Supports edge counting, subject to the applicable model functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSOE capture is particularly relevant when reconstructing the sequence of discrete events during process disturbances or equipment trips.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input ON threshold is 18 to 26.4 V DC, while an input voltage of 5.0 V DC or less is recognized as OFF. The rated input current is 4.1 mA +\/-20% per channel.\u003c\/p\u003e\n\u003cp\u003eThe 32 channels are arranged in groups sharing a common every 16 channels. All 24 V DC input signals connected to the module must have the same polarity. This wiring condition should be considered when grouping field contacts and voltage-fed signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIsolation and Input Response\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides electrical withstand capability of 2 kV AC for one minute between the input signal and system. The withstand voltage between channel-group commons is 500 V AC for one minute.\u003c\/p\u003e\n\u003cp\u003eFor status input, the specified response time is 8 ms or less. The pushbutton input function has a minimum ON detection time of 20 ms and a maximum ON\/OFF cycle of 25 Hz. These timing characteristics should be considered when selecting the module for event detection or pulse-counting signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration and Environmental Option\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe model code identifies the module as an ADV151 digital input unit with SOE capture. The -E suffix specifies SOE capture, 6 specifies a status display without explosion protection, and 3 specifies the ISA Standard G3 option with a temperature range of -20 to 70 deg C.\u003c\/p\u003e\n\u003cp\u003eThe status display provides a local indication for checking module status. The G3 option is relevant when selecting I\/O hardware for environments where corrosive gas exposure is a design consideration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Installation and Connection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-E version has an important installation restriction: it cannot be installed in an ER Bus Node Unit. Its SOE capture function is available only when installed in an ESB Bus Node Unit or an Optical ESB Bus Node Unit.\u003c\/p\u003e\n\u003cp\u003eSupported external connection arrangements include pressure-clamp terminals, the dedicated AKB331 cable, and MIL connector cables. The actual connection arrangement must match the selected terminal or cable interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-E63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/-20% per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Function\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms or less (status input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Input to System)\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Between Commons)\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute, common every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Option\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure-clamp terminal, AKB331 dedicated cable, or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV151-E63 support Sequence of Events recording?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The ADV151-E63 includes the SOE capture function. It captures input events for transfer to the Yokogawa SOE system, where time-stamped events can be stored and displayed chronologically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ADV151-E63 be installed in an ER Bus Node Unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The ADV151-E version is not permitted in ER Bus Node Units. Its SOE capture function is supported when installed in an ESB Bus Node Unit or Optical ESB Bus Node Unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be considered when wiring the 32 input channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The channels share a common every 16 channels. All connected 24 V DC input signals must have the same polarity. The selected terminal or cable interface must also match the installation configuration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69307889189106,"sku":"ADV151-E63","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ADV151-E632.jpg?v=1794535850","url":"https:\/\/www.petrospare.com\/products\/yokogawa-adv151-e63-digital-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}