{"product_id":"yokogawa-adv151-e63-d6a00-32-channel-isolated-digital-input-module","title":"Yokogawa ADV151-E63\/D6A00 32-Channel Isolated Digital Input Module","description":"\u003cp\u003eThe Yokogawa ADV151-E63\/D6A00 is a 32-channel isolated digital input module designed to receive 24 V DC ON\/OFF signals from field devices. It supports status detection and Sequence of Events (SOE) capture, allowing the control system to monitor discrete signal changes and record event information. The E63 configuration includes a status display, ISA Standard G3 option and extended operating temperature option.\u003c\/p\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-E receives discrete signals from field devices and converts their ON\/OFF states into digital input information for the control system. Its 32 input channels support both sink and source signal configurations, with a rated input voltage of 24 V DC.\u003c\/p\u003e\n\u003cp\u003eThe module provides three input functions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStatus Input: Detects the ON\/OFF state of field signals for process monitoring and control logic.\u003c\/li\u003e\n\u003cli\u003ePushbutton Input: Counts pushbutton signal edges, supporting applications that require discrete pulse or operation counting.\u003c\/li\u003e\n\u003cli\u003eSOE Input: Captures Sequence of Events data for recording changes in field signal states and supporting event analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SOE function is specific to the ADV151-E version. Its use requires the corresponding SOE system configuration.\u003c\/p\u003e\n\u003ch3\u003eElectrical Input Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module recognizes an input voltage of 18 to 26.4 V DC as ON and 5.0 V DC or less as OFF. The input current is 4.1 mA +\/-20% per channel at the rated voltage.\u003c\/p\u003e\n\u003cp\u003eThe input response time for status detection is 8 ms or less. For pushbutton input, the minimum ON detection time is 20 ms, with a maximum ON\/OFF cycle of 25 Hz.\u003c\/p\u003e\n\u003cp\u003eThe input channels share a common connection every 16 channels. All 24 V DC input signals connected to the module must have the same polarity. This condition should be considered when designing field wiring.\u003c\/p\u003e\n\u003ch3\u003eStatus Display and Environmental Configuration\u003c\/h3\u003e\n\u003cp\u003eThe E63 suffix configuration includes a status display for visual channel monitoring and an ISA Standard G3 option with an extended operating temperature range of -20 to 70 deg C.\u003c\/p\u003e\n\u003cp\u003eThe G3 option is intended for environments with corrosive gas exposure. The 6 configuration indicates a status display without explosion protection. Therefore, this version should not be treated as an explosion-protected module.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-E63\/D6A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eSink \/ Source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/-20% per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Isolation\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute, signal to system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Between Commons\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms or less for status input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ON Detection Time\u003c\/td\u003e\n\u003ctd\u003e20 ms for pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON\/OFF Cycle\u003c\/td\u003e\n\u003ctd\u003e25 Hz for pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eWith status display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Function\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Option\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSystem Configuration and Installation Considerations\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-E belongs to Yokogawa's FIO digital I\/O module family. The FIO architecture supports installation in designated ESB Bus Node Units and Field Control Units.\u003c\/p\u003e\n\u003cp\u003eThe following configuration restrictions and electrical conditions are relevant:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ADV151-E cannot be installed in an ER Bus Node Unit.\u003c\/li\u003e\n\u003cli\u003eThe module supports dual-redundant input configurations when used within a supported system architecture.\u003c\/li\u003e\n\u003cli\u003eAll 24 V DC input signals connected to the module must have the same polarity.\u003c\/li\u003e\n\u003cli\u003eWithstanding voltage between input signal and system depends on the external connection method. The dedicated cable specification is 500 V AC, while the MIL connector cable specification depends on the cable's electrical characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the difference between ADV151-E and ADV151-P?\u003c\/p\u003e\n\u003cp\u003eA: The ADV151-E provides SOE capture functionality, while the ADV151-P provides a pushbutton input function. Both versions support 32-channel, 24 V DC digital input operation.\u003c\/p\u003e\n\u003cp\u003eQ: Can ADV151-E be installed in an ER Bus Node Unit?\u003c\/p\u003e\n\u003cp\u003eA: No. Yokogawa specifies that ADV151-E cannot be installed in an ER Bus Node Unit. The applicable FIO node configuration must be checked before installation.\u003c\/p\u003e\n\u003cp\u003eQ: What should be checked when connecting field signals to ADV151-E?\u003c\/p\u003e\n\u003cp\u003eA: Verify the 24 V DC signal polarity, ON\/OFF voltage thresholds and common grouping. The module shares a common connection every 16 channels, so all connected input signals must have the same polarity.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69266116378866,"sku":"ADV151-E63\/D6A00","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ADV151-E63D6A00.jpg?v=1794281120","url":"https:\/\/www.petrospare.com\/products\/yokogawa-adv151-e63-d6a00-32-channel-isolated-digital-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}