{"product_id":"yokogawa-aav144-s00-a4s00-analog-input-module","title":"Yokogawa AAV144-S00\/A4S00 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AAV144-S00\/A4S00\u003c\/strong\u003e is a 16-channel isolated analog input module designed to receive DC voltage signals in the range of -10 to +10 V. It converts field voltage signals into digital data for processing by the control system. The specified configuration includes a pressure-clamp terminal block for analog signal wiring, model ATA4S-00.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAV144 receives voltage signals from field instruments and converts them into digital input data for the control system. Its 16-channel configuration supports multiple voltage measurement points through one module.\u003c\/p\u003e\n\u003cp\u003eThe input channels are isolated from the system side, while the individual channels are not insulated from one another. This distinction is important when checking field grounding arrangements and the electrical relationship between connected signal sources.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Specifications and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports two input ranges, 1 to 5 V DC and -10 to +10 V DC. For this -10 to +10 V configuration, the input accuracy is specified as +\/-20 mV. The input range is selected collectively for channels CH1 through CH16 rather than configured independently for each channel.\u003c\/p\u003e\n\u003cp\u003eThe 10 ms data update period determines how frequently updated input values become available to the control system. This makes the module suitable for voltage measurement loops where the specified update interval meets the application requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Isolation and Input Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAV144 provides isolation between the field input circuits and the control system, with a specified withstand voltage of 1500 V AC for 1 minute. However, there is no insulation between individual input channels. This distinction should be considered when connecting voltage sources with different grounding references.\u003c\/p\u003e\n\u003cp\u003eThe allowable input voltage is +\/-30 V DC. Input resistance is 1 MOhm when powered and 200 kOhm when the module is powered down. These values are relevant when checking signal-source loading and the electrical conditions during power-off states.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Block Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \/A4S00 option identifies a pressure-clamp terminal block for analog signals, model \u003cstrong\u003eATA4S-00\u003c\/strong\u003e. It provides the field wiring interface for the module. It is distinct from the \/K4A00 cable-interface option and the \/A4D00 dual pressure-clamp terminal configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAV144-S00\/A4S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternative Input Range\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power ON)\u003c\/td\u003e\n\u003ctd\u003e1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power OFF)\u003c\/td\u003e\n\u003ctd\u003e200 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (-10 to +10 V)\u003c\/td\u003e\n\u003ctd\u003e+\/-20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift (-10 to +10 V)\u003c\/td\u003e\n\u003ctd\u003e+\/-20 mV\/10 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eField-to-system isolation; no channel-to-channel insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eATA4S-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure-clamp terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of signals does the AAV144-S00\/A4S00 accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It accepts DC voltage signals in the -10 to +10 V or 1 to 5 V range. The input range is selected collectively for all 16 channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AAV144 provide isolation between individual input channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The module provides isolation between the field side and the control system, but not between individual input channels. Field wiring and grounding arrangements should account for this limitation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the \/A4S00 option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It specifies the pressure-clamp terminal block ATA4S-00 for analog signal wiring. It is a terminal connection configuration, not a different input signal type.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69351054967026,"sku":"AAV144-S00\/A4S00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AAV144-S00A4S001.jpg?v=1794800112","url":"https:\/\/www.petrospare.com\/products\/yokogawa-aav144-s00-a4s00-analog-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}