{"product_id":"yokogawa-aap149-s00-pulse-input-module","title":"Yokogawa AAP149-S00 Pulse Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AAP149-S00\u003c\/strong\u003e is a 16-channel pulse input module compatible with PM1. It receives pulse train signals from pulse input signal conditioner cards and counts incoming pulses for use by the control system. The module supports non-isolated transistor contact inputs, with an input frequency range of 0 to 6 kHz and a data update period of 2 ms.\u003c\/p\u003e\n\u003ch3\u003ePulse Input Function\u003c\/h3\u003e\n\u003cp\u003eThe AAP149-S00 processes pulse signals from field signal conditioning equipment. Each channel accepts a transistor contact (open collector) signal and detects pulses on the trailing edge. The module counts the incoming pulses and makes the resulting data available to the control system.\u003c\/p\u003e\n\u003cp\u003eIts 16 input channels share a non-isolated configuration. Unlike isolated pulse input modules, the AAP149 does not provide channel-to-channel or field-to-system electrical isolation as part of its specified input design.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAP149-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePulse Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003ePM1 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eTransistor contact (open collector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 6 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Detection Edge\u003c\/td\u003e\n\u003ctd\u003eTrailing edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e400 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eDedicated cable (KS2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eElectrical Signal and Data Processing\u003c\/h3\u003e\n\u003cp\u003eThe 0 to 6 kHz input frequency range defines the supported pulse repetition rate. The trailing-edge detection method determines which signal transition is counted as a pulse event. This distinction matters when checking the output of the upstream pulse signal conditioner.\u003c\/p\u003e\n\u003cp\u003eThe 2 ms data update period specifies how frequently updated input data is made available to the system. It should not be interpreted as the minimum pulse width or as a guaranteed end-to-end control response time.\u003c\/p\u003e\n\u003ch3\u003eOrdering Configuration\u003c\/h3\u003e\n\u003cp\u003eThe AAP149 model uses the following suffix structure:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-S\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe AAP149-S00 ordering code identifies the standard, basic configuration. The final digit is not the ISA Standard G3 option; that configuration is identified by AAP149-S01.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many pulse input channels does the AAP149-S00 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides 16 non-isolated pulse input channels. Each channel accepts a transistor contact (open collector) signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum supported input frequency?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified input frequency range is 0 to 6 kHz. Pulse detection is performed on the trailing edge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What connection cable is required for the AAP149-S00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified external connection is a dedicated KS2 cable. The cable and associated interface arrangement should be checked against the installed PM1 configuration before replacement or installation.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69351054442738,"sku":"AAP149-S00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AAP149-S00.jpg?v=1794799884","url":"https:\/\/www.petrospare.com\/products\/yokogawa-aap149-s00-pulse-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}