{"product_id":"yokogawa-aap135-s00-13s00-pulse-input-module","title":"Yokogawa AAP135-S00\/13S00 Pulse Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AAP135-S00\/13S00\u003c\/strong\u003e is an 8-channel isolated pulse input module designed to receive contact ON\/OFF, voltage pulse, and current pulse signals. It supports input frequencies up to 10 kHz and accepts both 2-wire and 3-wire field signal configurations. The \/13S00 ordering option specifies a pressure clamp terminal block for pulse signal connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAP135 receives pulse signals from field devices and transfers the input information to the control system. Its eight channels are electrically isolated from one another and from the system side, allowing signals from separate field circuits to be handled independently.\u003c\/p\u003e\n\u003cp\u003eSupported input signal configurations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-wire signals:\u003c\/strong\u003e Contact ON\/OFF, voltage pulse, and current pulse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-wire signals:\u003c\/strong\u003e Power-supply-type voltage pulse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent pulse processing:\u003c\/strong\u003e Current input is converted to a voltage signal internally.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-redundant configuration:\u003c\/strong\u003e Supported by the module design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module accepts pulse signals with frequencies from 0 to 10 kHz and a minimum pulse width of 40 us. For voltage and current pulse inputs, the specified high-level and low-level ranges determine the acceptable signal thresholds. The input source resistance must also be considered when selecting field transmitters.\u003c\/p\u003e\n\u003cp\u003eFor contact inputs, the module recognizes relay and transistor contact states using specified open- and closed-circuit resistance levels. A configurable filter is available to eliminate contact chattering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Input Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input thresholds distinguish valid pulse states from noise or inactive signal levels. For voltage and current pulse inputs, the current signal is internally converted to voltage before processing.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-level voltage (VH): 3 to 24 V DC.\u003c\/li\u003e\n\u003cli\u003eLow-level voltage (VL): -1 to 8 V DC.\u003c\/li\u003e\n\u003cli\u003eMinimum voltage swing (VH - VL): 3 V.\u003c\/li\u003e\n\u003cli\u003eMaximum signal source resistance: 1 kOhm.\u003c\/li\u003e\n\u003cli\u003eContact open resistance: 100 kOhm or more.\u003c\/li\u003e\n\u003cli\u003eContact closed resistance: 200 Ohm or less.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module also provides selectable shunt resistance values of none, 200 Ohm, 500 Ohm, or 1000 Ohm. Its 68 kOhm pull-up resistance supports 12 V DC or 24 V DC signal configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTransmitter Power and Signal Conditioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe transmitter power supply can be selected between 12 V DC and 24 V DC. The corresponding current limiter values are 40 mA at 12 V DC +\/-10% and 30 mA at 24 V DC +\/-10%.\u003c\/p\u003e\n\u003cp\u003eA configurable filter handles contact chattering. For dry-contact pulse signals between terminals B and C, the specified input frequency range is limited to 0 to 800 Hz rather than the general 0 to 10 kHz rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Connection and Ordering Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \/13S00 option identifies the \u003cstrong\u003eATI3S-00 pressure clamp terminal block for pulse signals\u003c\/strong\u003e. This provides a pressure-clamp field wiring interface for connecting the pulse input circuits.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's ordering information identifies the following configuration codes:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-S\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eWith explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 and temperature (-20 to 70 deg C) option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/13S00\u003c\/td\u003e\n\u003ctd\u003ePressure Clamp Terminal Block for Pulse, ATI3S-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/13S10\u003c\/td\u003e\n\u003ctd\u003ePressure Clamp Terminal Block for Pulse with surge absorber, ATI3S-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/13D00\u003c\/td\u003e\n\u003ctd\u003eDual Pressure Clamp Terminal Block for Pulse, ATI3D-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/13D10\u003c\/td\u003e\n\u003ctd\u003eDual Pressure Clamp Terminal Block for Pulse with surge absorber, ATI3D-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAP135-S00\/13S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePulse Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e8, isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eContact ON\/OFF, voltage pulse, current pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Configuration\u003c\/td\u003e\n\u003ctd\u003e2-wire and 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDry Contact Input Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 800 Hz between terminals B and C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Input Pulse Width\u003c\/td\u003e\n\u003ctd\u003e40 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Level Input Voltage\u003c\/td\u003e\n\u003ctd\u003e3 to 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-Level Input Voltage\u003c\/td\u003e\n\u003ctd\u003e-1 to 8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Voltage Swing\u003c\/td\u003e\n\u003ctd\u003e3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Signal Source Resistance\u003c\/td\u003e\n\u003ctd\u003e1 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Open Resistance\u003c\/td\u003e\n\u003ctd\u003e100 kOhm or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Closed Resistance\u003c\/td\u003e\n\u003ctd\u003e200 Ohm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShunt Resistance\u003c\/td\u003e\n\u003ctd\u003eNone \/ 200 \/ 500 \/ 1000 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePull-up Resistance\u003c\/td\u003e\n\u003ctd\u003e68 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter\u003c\/td\u003e\n\u003ctd\u003eConfigurable chattering elimination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power Supply\u003c\/td\u003e\n\u003ctd\u003eSelectable 12 V DC \/ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e300 mA (5 V DC), 400 mA (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute, input-to-system and channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal block, KS cable, MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Option\u003c\/td\u003e\n\u003ctd\u003eATI3S-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many pulse input channels does the AAP135-S00\/13S00 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides eight electrically isolated pulse input channels. Each channel supports the specified contact, voltage pulse, or current pulse input configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the \/13S00 suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/13S00 option specifies the ATI3S-00 pressure clamp terminal block for pulse signal connections. It identifies the terminal connection configuration rather than an additional input channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AAP135-S00\/13S00 be used in a redundant configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The AAP135 supports dual-redundant configuration. The module's isolation and shunt behavior are designed to support this arrangement, with the shunt circuit open on the standby side.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69310316577010,"sku":"AAP135-S00\/13S00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AAP135-S0013S002.jpg?v=1794539555","url":"https:\/\/www.petrospare.com\/products\/yokogawa-aap135-s00-13s00-pulse-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}