{"product_id":"yokogawa-aai841-h00-ccc01-analog-i-o-module","title":"Yokogawa AAI841-H00\/CCC01 Analog I\/O Module","description":"\u003cp\u003eThe Yokogawa AAI841-H00\/CCC01 is a non-isolated analog I\/O module providing 8 current input channels and 8 current output channels, each using a 4 to 20 mA signal range. The HART communication option supports digital communication with compatible field devices, while the CCC01 option specifies a connector cover for MIL cable connections (model ACCC01).\u003c\/p\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe AAI841 combines analog signal acquisition and output control in one module. Its eight input channels receive 4 to 20 mA signals from field transmitters, while eight output channels provide 4 to 20 mA signals to receiving devices such as control valves or other current-operated equipment.\u003c\/p\u003e\n\u003cp\u003eThe non-isolated channel configuration is an important consideration when checking field wiring and grounding arrangements. Input and output circuit isolation should not be assumed when integrating this module into an existing I\/O configuration.\u003c\/p\u003e\n\u003ch3\u003eHART Communication\u003c\/h3\u003e\n\u003cp\u003eThe H suffix identifies the HART digital communication option. In addition to conventional 4 to 20 mA process signals, HART communication allows the control system to access supported digital field-device information. Yokogawa documentation describes reading HART variables through HART Command #3.\u003c\/p\u003e\n\u003cp\u003eThis capability provides access to digital device information alongside the analog process value, subject to the connected field device and system configuration.\u003c\/p\u003e\n\u003ch3\u003eConnector Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \/CCC01 option specifies a connector cover for MIL cable, identified by Yokogawa as ACCC01. This option should be considered when checking the module's cable connection arrangement and replacement configuration.\u003c\/p\u003e\n\u003cp\u003eThe 00 suffix identifies the basic type. The complete ordering code should be retained when selecting a replacement, rather than identifying the module by AAI841 alone.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAI841-H00\/CCC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O Module (Current I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Communication\u003c\/td\u003e\n\u003ctd\u003eHART protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e±16 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Option\u003c\/td\u003e\n\u003ctd\u003eMIL cable connector cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Cover Model\u003c\/td\u003e\n\u003ctd\u003eACCC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOrdering Code Identification\u003c\/h3\u003e\n\u003cp\u003eThe complete model number identifies the module's communication and connection configuration:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAAI841\u003c\/td\u003e\n\u003ctd\u003e8-channel input \/ 8-channel output analog I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eHART digital communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CCC01\u003c\/td\u003e\n\u003ctd\u003eMIL cable connector cover, ACCC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the AAI841-H00\/CCC01 support both analog input and analog output?\u003c\/p\u003e\n\u003cp\u003eA: Yes. It provides eight 4 to 20 mA input channels and eight 4 to 20 mA output channels. Both functions are integrated into the same non-isolated module.\u003c\/p\u003e\n\u003cp\u003eQ: What is the difference between AAI841-H00 and AAI841-S00?\u003c\/p\u003e\n\u003cp\u003eA: The H suffix identifies the HART digital communication version, while S identifies the standard type. The H version supports digital communication with compatible HART field devices in addition to analog signal processing.\u003c\/p\u003e\n\u003cp\u003eQ: What does the CCC01 option include?\u003c\/p\u003e\n\u003cp\u003eA: CCC01 specifies a connector cover for MIL cable, identified as ACCC01. It is a connection-related ordering option and should be retained when replacing an existing module with the same configuration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69266073026802,"sku":"AAI841-H00\/CCC01","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AAI841-H00CCC01.jpg?v=1794280446","url":"https:\/\/www.petrospare.com\/products\/yokogawa-aai841-h00-ccc01-analog-i-o-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}