{"product_id":"yokogawa-aai135-s50-ccc01-analog-input-module","title":"Yokogawa AAI135-S50\/CCC01 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AAI135-S50\/CCC01\u003c\/strong\u003e is an 8-channel analog input module designed to receive 4-20 mA DC signals from field instruments. Its isolated input channels allow individual current-loop signals to be acquired by the control system while maintaining electrical isolation between channels. The \/CCC01 option specifies a connector cover for the MIL cable connection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI135 receives analog current signals from field transmitters and converts them into measurement data for the control system. The 4-20 mA input range is commonly used for transmitting process variables such as pressure, flow, level and temperature.\u003c\/p\u003e\n\u003cp\u003eEach of the eight input channels is isolated. This arrangement helps prevent electrical potential differences and ground-loop currents on one signal circuit from directly affecting other input channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Characteristics and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module accepts 4-20 mA DC signals and provides an input update period of \u003cstrong\u003e10 ms\u003c\/strong\u003e. Its specified measurement accuracy is +\/-16 uA, allowing the control system to process field measurements with a defined accuracy limit.\u003c\/p\u003e\n\u003cp\u003eThe input resistance varies with the loop current when the module is powered. This resistance should be considered when checking transmitter output capability and calculating the voltage available across the field wiring and input circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Isolation and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI135 provides isolation between the field input and the system, as well as between individual input channels. The specified withstand voltage is 500 V AC for 1 minute, both between input and system and between input channels.\u003c\/p\u003e\n\u003cp\u003eFor MIL connector cable installations, the actual withstand voltage depends on the electrical specifications of the selected cable. Yokogawa also specifies that a Zener barrier must not be connected to this module; an isolation barrier is required for intrinsically safe applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI135-S50\/CCC01 ordering code identifies the following configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAAI135:\u003c\/strong\u003e 8-channel isolated analog input module for 4-20 mA signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-S:\u003c\/strong\u003e Standard type, without the HART communication option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5:\u003c\/strong\u003e No explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0:\u003c\/strong\u003e Basic type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/CCC01:\u003c\/strong\u003e Connector cover for MIL cable, model ACCC01.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CCC01 option identifies the connector cover rather than a different input-channel configuration. It is important to distinguish this option from pressure-clamp terminal block configurations when checking replacement hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAI135-S50\/CCC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated between channels and between input and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power ON)\u003c\/td\u003e\n\u003ctd\u003e290 ohm at 20 mA to 450 ohm at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power OFF)\u003c\/td\u003e\n\u003ctd\u003e500 kohm or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e15.0 V or more at 20 mA; 29.3 V or less at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA\/10 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e360 mA at 5 V DC; 450 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eMIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Option\u003c\/td\u003e\n\u003ctd\u003e\/CCC01, connector cover ACCC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AAI135-S50\/CCC01 support HART communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The -S suffix identifies the standard type. The AAI135-H variant is the version specified for HART digital communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the CCC01 option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: CCC01 provides a connector cover for the MIL cable connection. It does not change the module's eight-channel input capacity or 4-20 mA signal type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AAI135-S50\/CCC01 be used in intrinsically safe applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module does not permit direct connection to a Zener barrier. An isolation barrier is required when using it in intrinsically safe applications. The selected barrier and field wiring must also satisfy the applicable installation requirements.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69351041073394,"sku":"AAI135-S50\/CCC01","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AAI135-S50CCC01.jpg?v=1794799308","url":"https:\/\/www.petrospare.com\/products\/yokogawa-aai135-s50-ccc01-analog-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}