{"product_id":"yokogawa-aab841-s00-analog-input-output-module","title":"Yokogawa AAB841-S00 Analog Input\/Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AAB841-S00\u003c\/strong\u003e is identified as an analog input\/output module for industrial control system applications. Its exact channel configuration, signal characteristics, electrical ratings, and system interface should be verified against the applicable Yokogawa documentation before specifying it for a replacement or maintenance project.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunction and Signal Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAccording to Yokogawa's analog I\/O module specifications, the AAB841 provides \u003cstrong\u003e8 analog input channels and 8 analog output channels\u003c\/strong\u003e, supporting up to eight control loops. The input channels accept 1 to 5 V DC signals, while the output channels provide 4 to 20 mA DC signals. This arrangement allows the control system to acquire voltage-based process measurements and transmit current-based control commands through one module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput and Output Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input section uses differential, non-isolated signal processing. Its allowable common-mode voltage is +\/-1 V or less, and the specified input resistance is at least 1 MOhm when powered. The output section supports a load resistance of 0 to 750 Ohm, which should be checked against the connected field device and cable circuit.\u003c\/p\u003e\n\u003cp\u003eThe module provides a 10 ms data update period. Its specified input step response time is 100 ms, while the output step response time is 40 ms. These values describe different stages of signal processing and should not be treated as interchangeable response specifications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAB841-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eDifferential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Common-Mode Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-1 V or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power ON)\u003c\/td\u003e\n\u003ctd\u003e1 MOhm or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power OFF)\u003c\/td\u003e\n\u003ctd\u003e340 kOhm or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Output Load Resistance\u003c\/td\u003e\n\u003ctd\u003e0 to 750 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit-Open Detection\u003c\/td\u003e\n\u003ctd\u003eLess than 0.65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-4 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-48 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Step Response Time\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Step Response Time\u003c\/td\u003e\n\u003ctd\u003e40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e310 mA (5 V DC), 250 mA (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Signal Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe non-isolated design is an important consideration when connecting the AAB841 to field instrumentation. The differential input arrangement provides a defined common-mode voltage limit, but it does not provide galvanic isolation between the field signals and the system.\u003c\/p\u003e\n\u003cp\u003eYokogawa specifies that a Zener barrier must not be connected to this module for current output applications. An isolation barrier should be used when the module is applied in intrinsically safe circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many field signals can the AAB841-S00 handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides 8 analog input channels and 8 analog output channels, supporting up to eight input\/output control loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AAB841-S00 accept 4 to 20 mA input signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The specified input signal is 1 to 5 V DC. The 4 to 20 mA signal is used for the module's output channels. For applications requiring 4 to 20 mA input, the appropriate module specification must be checked separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AAB841-S00 provide electrical isolation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. It is a non-isolated analog I\/O module. External isolation requirements must be considered when designing field signal connections, particularly for intrinsically safe applications.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69351023313138,"sku":"AAB841-S00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AAB841-S03M4A001.jpg?v=1794453810","url":"https:\/\/www.petrospare.com\/products\/yokogawa-aab841-s00-analog-input-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}