{"product_id":"yokogawa-a2sam105-h000-s2-current-input-voltage-input-adaptor","title":"Yokogawa A2SAM105-H000 S2 Current Input\/Voltage Input Adaptor","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa A2SAM105-H000 S2\u003c\/strong\u003e is a current input\/voltage input adaptor designed to interface analog field signals with Yokogawa control system I\/O hardware. It supports 4-20 mA DC current signals and 0-10 V DC voltage signals. The -H suffix specifies digital communication using the HART protocol, allowing supported smart field instruments to exchange digital communication over the analog signal loop.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Signal and HART Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe adaptor accepts current or voltage input signals from field instruments. These two signal types have different electrical characteristics, so the input configuration and field wiring must match the connected transmitter.\u003c\/p\u003e\n\u003cp\u003eThe HART communication option allows digital instrument communication alongside the analog process signal. This supports access to compatible field-device information without treating the adaptor as a conventional analog input module with an independently specified channel count.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input ranges and electrical limits are distinct. The rated ranges define the normal measurement range, while the allowable input limits define the permitted electrical boundaries.\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA2SAM105-H000 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCurrent Input\/Voltage Input Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e0 to 25 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Resistance\u003c\/td\u003e\n\u003ctd\u003e1 MOhm (power-on); 100 kOhm or higher (power-off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Resistance\u003c\/td\u003e\n\u003ctd\u003e320 to 640 Ohm (power-on, depending on input current); 100 kOhm or higher (power-off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power Supply\u003c\/td\u003e\n\u003ctd\u003e15.0 V DC minimum at 20 mA; 24.0 V DC maximum at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Communication\u003c\/td\u003e\n\u003ctd\u003eHART 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e2 ms for adaptor alone; maximum 10 ms with the I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e42 mA at 24 V DC; 10 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eA2BN3D base plate for adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible I\/O Module Requirement\u003c\/td\u003e\n\u003ctd\u003eA2MMM843 Style 2 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Processing and Accuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe adaptor provides separate electrical input characteristics for voltage and current signals. Its input resistance affects the load presented to the field transmitter, particularly in current-loop applications where additional resistance can reduce the available transmitter voltage.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's specified accuracy varies with ambient temperature:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Type\u003c\/th\u003e\n\u003cth\u003e23 deg C +\/- 2 deg C\u003c\/th\u003e\n\u003cth\u003e0 to 60 deg C\u003c\/th\u003e\n\u003cth\u003e-40 to 70 deg C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e+\/-4 mV\u003c\/td\u003e\n\u003ctd\u003e+\/-8 mV\u003c\/td\u003e\n\u003ctd\u003e+\/-12 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input\u003c\/td\u003e\n\u003ctd\u003e+\/-12 uA\u003c\/td\u003e\n\u003ctd\u003e+\/-24 uA\u003c\/td\u003e\n\u003ctd\u003e+\/-40 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe input signal type and measurement range are configured through system software. For current inputs, the transmitter power supply can be configured for 2-wire or 4-wire transmitter connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHART Communication and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe -H option provides HART 7 communication for compatible field instruments. This allows the control system to obtain digital instrument information in addition to the conventional 4-20 mA process signal. Up to five HART field devices can be connected through a supported multidrop configuration.\u003c\/p\u003e\n\u003cp\u003eThe S2 protection behavior is relevant when diagnosing abnormal current-loop conditions. When overcurrent protection operates, the system does not report an Adaptor Fail alarm to the HIS; instead, the abnormal input condition is detected as IOP (input open). When the adaptor is powered off or overcurrent is detected, the current input loop becomes open.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel and Suffix Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer's ordering information identifies the A2SAM105 model and its suffix configuration as follows:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA2SAM105\u003c\/td\u003e\n\u003ctd\u003eCurrent Input\/Voltage Input Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-H\u003c\/td\u003e\n\u003ctd\u003eWith digital communication (HART protocol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eWith no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe complete ordering designation \u003cstrong\u003eA2SAM105-H000\u003c\/strong\u003e therefore identifies the HART-enabled, non-explosion-protected basic configuration. S2 is retained in the supplied product designation to distinguish the hardware style.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the A2SAM105-H000 S2 accept both 4-20 mA and 0-10 V DC signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It supports both signal types, but the input signal type and range must be configured through the system software to match the connected field instrument.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the A2SAM105-H000 S2 support HART communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Its -H configuration supports HART 7 communication. Up to five HART field devices can be connected through a supported multidrop arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when replacing an existing A2SAM105-H000 S2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the signal type, transmitter wiring, HART requirements, base plate arrangement and I\/O module revision. The adaptor requires an A2MMM843 Style 2 or later when used in the N-IO configuration. \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69411701096690,"sku":"A2SAM105-H000 S2","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/A2SAM105-H000S22.jpg?v=1795158623","url":"https:\/\/www.petrospare.com\/products\/yokogawa-a2sam105-h000-s2-current-input-voltage-input-adaptor","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}