{"product_id":"yokogawa-a1br4d-05-rtd-input-terminal-board","title":"Yokogawa A1BR4D-05 RTD Input Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa A1BR4D-05\u003c\/strong\u003e is a terminal board for resistance temperature detector (RTD) input signals in the CENTUM VP Field Control Unit (FIO) system. Based on the A1BR4D model, it provides field signal termination for single or dual-redundant I\/O configurations. The -05 ordering code identifies the basic version without explosion protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA1BR4D-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eA1BR4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTD Input Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003e16 points x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnected I\/O Module\u003c\/td\u003e\n\u003ctd\u003eAAR145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003ePressure clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Termination and Module Connection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe A1BR4D provides 16 RTD input channels through pressure-clamp terminals. It connects to the Yokogawa AAR145 resistance temperature detector input module using the AKB335 signal cable. The terminal assignments include A, B, and C connections for each channel, supporting the RTD and potentiometer input arrangements specified for AAR145.\u003c\/p\u003e\n\u003cp\u003eFor single operation, the I\/O module connects through connector CN1. For dual-redundant operation, both CN1 and CN2 are used. The terminal board therefore provides the field wiring interface for the corresponding single or redundant I\/O arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Wiring Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation resistance: 10 Mohm or greater at 200 VDC.\u003c\/li\u003e\n\u003cli\u003eWithstanding voltage: 200 VAC for 1 minute, between channels.\u003c\/li\u003e\n\u003cli\u003eRecommended conductor cross-section: 0.5 to 2 mm2 (AWG 20 to 14) without a sleeve.\u003c\/li\u003e\n\u003cli\u003eSignal cable temperature rating: Ambient temperature plus 10 deg C or higher.\u003c\/li\u003e\n\u003cli\u003eRTD wiring: The wiring resistance of the IN□A and IN□B signal cables must be identical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese requirements should be considered when selecting field wiring and preparing the RTD signal connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Code\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA1BR4D\u003c\/td\u003e\n\u003ctd\u003eTerminal Board for RTD input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-0\u003c\/td\u003e\n\u003ctd\u003eFixed code; always 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-5\u003c\/td\u003e\n\u003ctd\u003eBasic type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe complete ordering number \u003cstrong\u003eA1BR4D-05\u003c\/strong\u003e identifies the basic terminal board configuration without explosion protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which I\/O module is used with the A1BR4D-05?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified connected module is the Yokogawa AAR145 RTD input module. The corresponding signal cable is AKB335.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the A1BR4D-05 support dual-redundant operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. For dual-redundant I\/O configurations, both CN1 and CN2 connectors are used. For single operation, only CN1 is connected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the A1BR4D-05 provide explosion protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The -5 suffix identifies the basic type without explosion protection. It should not be confused with explosion-protected ordering variants.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69396678869234,"sku":"A1BR4D-05","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SARM15A-000.jpg?v=1794798848","url":"https:\/\/www.petrospare.com\/products\/yokogawa-a1br4d-05-rtd-input-terminal-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}