{"product_id":"schneider-electric-tsx3708056dr1-modicon-tsx-micro-modular-base-controller","title":"Schneider Electric TSX3708056DR1 Modicon TSX Micro Modular Base Controller","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric TSX3708056DR1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTSX3708056DR1\u003c\/strong\u003e Modular Base Controller, operates as a dedicated PLC hardware component for discrete I\/O execution and serial communication within the Modicon TSX Micro automation platform. This controller integrates 32 discrete inputs, 24 relay outputs, Uni-Telway and Modbus RTU interfaces for machine control applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSX3708056DR1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModular Base Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon TSX Micro automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e244.9 mm W x 152 mm D x 151 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 W useful secondary power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC, 90 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e32 inputs, 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e24 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Communication\u003c\/td\u003e\n\u003ctd\u003e1 x Uni-Telway serial link 19.2 kbit\/s; 1 x Modbus RTU 19.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal RAM\u003c\/td\u003e\n\u003ctd\u003e11 Kwords data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e12 Kwords data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Execution Time\u003c\/td\u003e\n\u003ctd\u003e0.25 us Boolean without PCMCIA card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity to Microbreaks\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eOverload protection, short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Backplane Communication and I\/O Architecture\u003c\/h3\u003e\n\u003cp\u003eThe TSX3708056DR1 provides a modular PLC base structure with three expansion slots and integrated discrete I\/O processing. The controller executes one master task, one fast task, and up to eight event tasks. Internal memory allocation includes RAM data storage and Flash data storage for application handling.\u003c\/p\u003e\n\u003cp\u003eThe controller supports deterministic serial communication through Uni-Telway and Modbus RTU links at 19.2 kbit\/s. Its I\/O density configuration includes 32 24 VDC discrete inputs and 24 relay outputs connected through screw terminal interfaces.\u003c\/p\u003e\n\u003cp\u003eFor Schneider Electric PLC platforms, firmware flash compatibility and backplane bus communication define module integration behavior within the TSX Micro architecture. Expansion modules must match the supported TSX Micro hardware configuration and communication addressing structure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of I\/O is integrated into the TSX3708056DR1 controller?\u003cbr\u003eA: The controller contains 32 discrete 24 VDC inputs and 24 relay outputs through a screw terminal discrete I\/O interface.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication protocols are available on the TSX3708056DR1?\u003cbr\u003eA: The controller provides one Uni-Telway serial communication link and one Modbus RTU serial communication link, both operating at 19.2 kbit\/s.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TSX3708056DR1 operate with modern Modicon PLC expansion systems?\u003cbr\u003eA: The TSX3708056DR1 belongs to the discontinued Modicon TSX Micro platform. Compatibility depends on the existing TSX Micro hardware architecture and supported replacement solutions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the TSX3708056DR1 in accordance with the Modicon TSX Micro hardware installation requirements. Verify the power supply range before connection and maintain separation between AC power wiring, relay output circuits, and low-level communication cables.\u003c\/p\u003e\n\u003cp\u003eUse proper grounding practices for the PLC chassis and communication cable shields. Serial communication wiring should follow the recommended cable routing method to reduce electromagnetic interference. Confirm terminal tightening, module seating, and I\/O addressing before system commissioning.\u003c\/p\u003e\n\u003cp\u003eThe controller was discontinued on Dec 31, 2019 and reached end-of-service status on Jan 22, 2021. No direct replacement was specified by Schneider Electric.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67724468224242,"sku":"TSX3708056DR1","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/TSX3708056DR12.jpg?v=1791878879","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-tsx3708056dr1-modicon-tsx-micro-modular-base-controller","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}