{"product_id":"schneider-electric-tm3xrec1-modicon-tm3-remote-receiver-module","title":"Schneider Electric TM3XREC1 Modicon TM3 Remote Receiver Module","description":"\u003cp\u003eConfigured for remote I\/O expansion in Modicon M221, M241, M251, and M262 controller systems, the \u003cstrong\u003eSchneider Electric TM3XREC1\u003c\/strong\u003e (\u003cstrong\u003eTM3XREC1\u003c\/strong\u003e Remote Receiver Module) receives bus connections from a remote transmitter through an RJ45 expansion cable. It supports up to 7 I\/O expansion modules, operates with a 24 VDC supply, and distributes bus data and power through the Modicon TM3 expansion interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTM3XREC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon TM3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRemote Receiver Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eModicon M221, M241, M251, M262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Tolerance\u003c\/td\u003e\n\u003ctd\u003e-15% to +20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e40 mA at 24 VDC via bus connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Bus Output Current\u003c\/td\u003e\n\u003ctd\u003e560 mA at 5 V; 560 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003eRJ45 bus transmitter connector; removable 3-terminal screw block for 24 VDC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eGreen power LED; green Link LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTH35-15 or TH35-7.5 DIN rail; plate or panel with fixing kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e23.65 x 73.3 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.075 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C horizontal; -10 to 50 deg C vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e3.5 mm at 5-8.4 Hz; 3 gn at 8.4-150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e15 gn for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility\u003c\/td\u003e\n\u003ctd\u003eIEC 55011 Class A radiated emissions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, UL 508, CSA C22.2 No. 142, UL 1604, CSA C22.2 No. 213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications and Markings\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, RCM, EAC, cULus, CSA HazLoc, GOST, Merchant Navy, C-Tick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e21 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRemote I\/O Bus Communication and Power Distribution\u003c\/h3\u003e\n\u003cp\u003eThe TM3XREC1 provides the receiver-side interface for remote Modicon TM3 I\/O expansion. An RJ45 connection links the receiver to the bus transmitter, while the removable screw terminal block connects the external 24 VDC supply.\u003c\/p\u003e\n\u003cp\u003eThe expansion bus distributes data and power between compatible controller and I\/O components. The specified maximum expansion count is 7 modules. The receiver's 40 mA current consumption and 1 W maximum power dissipation should be considered when checking the electrical load and thermal conditions of the installation.\u003c\/p\u003e\n\u003cp\u003eThe listed expansion bus output current ratings are 560 mA at 5 V and 560 mA at 24 V. These ratings should not be interpreted as proof that both supplies can deliver their maximum rated currents simultaneously under every system configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Modicon controllers are compatible with the TM3XREC1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module is listed for use with Modicon M221, M241, M251, and M262 logic controllers. Confirm the controller hardware and configuration requirements before commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power supply and current consumption does the receiver require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The rated supply is 24 VDC, with a tolerance of -15% to +20%. The specified current consumption is 40 mA at 24 VDC via the bus connector, and maximum power dissipation is 1 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What installation conditions must be observed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Maintain the specified operating temperature for the mounting orientation: -10 to 55 deg C horizontally or -10 to 50 deg C vertically. The enclosure rating is IP20, so the module requires installation in an environment that provides appropriate protection against dust and water ingress.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the receiver on a compatible TH35-15 or TH35-7.5 DIN rail, or use the specified plate or panel fixing kit. Secure the module before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower wiring:\u003c\/strong\u003e Connect the external 24 VDC supply through the removable 3-terminal screw block. Verify polarity and supply voltage before energizing the assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus connection:\u003c\/strong\u003e Connect the RJ45 interface to the corresponding bus transmitter using the designated expansion cable. Verify the cable specification and permitted routing against the Schneider Electric installation documentation; the supplied data does not establish an unambiguous cable-length limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and shielding:\u003c\/strong\u003e Follow the controller and cable manufacturer's grounding and shielding instructions. Keep communication wiring separated from high-current switching conductors where practical to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal clearance:\u003c\/strong\u003e Observe the operating temperature limits for the selected mounting orientation. Avoid installation adjacent to components that produce excessive heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Check the green power and Link LEDs after energizing. Verify the controller configuration, expansion-module count, bus communication, and I\/O status before enabling the controlled process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental protection:\u003c\/strong\u003e The IP20 enclosure is intended for protected installation. Prevent conductive contamination, condensation, and exposure to liquids.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67666313445618,"sku":"TM3XREC1","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/TM3XREC12.jpg?v=1791620746","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-tm3xrec1-modicon-tm3-remote-receiver-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}