{"product_id":"schneider-electric-tm3dq32tk-modicon-tm3-discrete-output-module","title":"Schneider Electric TM3DQ32TK Modicon TM3 Discrete Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric TM3DQ32TK\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTM3DQ32TK\u003c\/strong\u003e discrete output module, provides 32 transistor outputs with positive logic (PNP\/source) for Modicon M221, M241, M251, and M262 controllers. It switches 24 VDC output circuits through HE-10 connectors and supports control of variable speed drives and other devices with current or voltage inputs. The module communicates with the controller through the TM3 bus expansion connector and provides channel-level LED status indication.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTM3DQ32TK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon TM3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eTaiwan (TW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e32 transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic, source (PNP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per transistor output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Turn-On Time\u003c\/td\u003e\n\u003ctd\u003e450 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Turn-Off Time\u003c\/td\u003e\n\u003ctd\u003e450 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 0.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tungsten Load\u003c\/td\u003e\n\u003ctd\u003eLess than 1.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC: 5 mA typical; 24 VDC: 0 mA typical, as listed in the main specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Logic Supply\u003c\/td\u003e\n\u003ctd\u003ePowered by internal bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC between outputs and internal logic; outputs are not isolated from each other\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eHE-10 output connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Distance\u003c\/td\u003e\n\u003ctd\u003e5 m with unshielded transistor output cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003eOne green LED per output channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e33.5 x 81.3 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.112 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTH35-15 or TH35-7.5 DIN rail; panel mounting with fixing kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C horizontal; -10 to 35 deg C vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e15 gn for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, cULus, UKCA, RCM, EAC, cULus HazLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eModicon M221, M241, M251, M262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure Machine Expert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Reference\u003c\/td\u003e\n\u003ctd\u003eTM3 Digital I\/O Modules Firmware V28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611513\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e50 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTransistor Output Operation and Bus Interface\u003c\/h3\u003e\n\u003cp\u003eThe TM3DQ32TK uses source-type transistor outputs to switch positive 24 VDC signals to connected loads. Each channel supports a specified output current of 100 mA, subject to the electrical requirements of the connected device and the controller system's overall power budget.\u003c\/p\u003e\n\u003cp\u003eThe module receives its internal operating power and exchanges data through the TM3 expansion bus. The stated 500 VAC isolation separates the output circuits from internal logic; it does not provide channel-to-channel isolation. Each output has an individual green status LED for checking commanded output states.\u003c\/p\u003e\n\u003cp\u003eThe module connects to external wiring through HE-10 connectors. The maximum specified distance for unshielded transistor output cable is 5 m. External devices must be compatible with the module's positive-logic output arrangement and electrical ratings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the TM3DQ32TK directly drive a variable speed drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, when the drive provides a compatible current or voltage command input and the electrical interface matches the module's 24 VDC PNP\/source output characteristics. Verify the drive input specifications before wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are the 32 output channels electrically isolated from one another?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The module specifies 500 VAC isolation between the outputs and internal logic, but the output channels are not isolated from each other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What cable length and mounting conditions should be observed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified maximum cable distance for unshielded transistor output wiring is 5 m. The module supports TH35-15 and TH35-7.5 DIN rails or panel mounting with a fixing kit. Observe the installation-specific temperature limit of -10 to 55 deg C horizontally or -10 to 35 deg C vertically.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the module on a compatible IEC 60715 TH35 DIN rail or secure it to a panel using the specified fixing kit. Maintain the correct orientation and observe the applicable operating temperature limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus connection:\u003c\/strong\u003e Align and engage the TM3 expansion connector with the adjacent controller or expansion module. Confirm mechanical engagement before applying power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput wiring:\u003c\/strong\u003e Connect field devices through the HE-10 connectors. Verify polarity and confirm that each load is compatible with 24 VDC positive-logic source outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad assessment:\u003c\/strong\u003e Keep each output within its 100 mA rating. Check the aggregate load, external supply capacity, and connected device input requirements before commissioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable routing:\u003c\/strong\u003e Keep output wiring separated from high-noise power conductors where practical. Observe the 5 m maximum cable distance specified for unshielded transistor output wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and shielding:\u003c\/strong\u003e Follow the controller and cabinet grounding design. Terminate cable shields according to the installation's EMC requirements; do not treat the output-to-logic isolation rating as a substitute for protective grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Verify controller compatibility, confirm the applicable firmware and EcoStruxure Machine Expert configuration, and test each output channel individually. Use the channel LEDs to check output status during functional testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental limits:\u003c\/strong\u003e Confirm IP20 enclosure protection is suitable for the installation. Provide an appropriate enclosure where protection against dust, moisture, or accidental contact is required.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67666261180658,"sku":"TM3DQ32TK","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/TM3DQ32TK2.jpg?v=1791619776","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-tm3dq32tk-modicon-tm3-discrete-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}