{"product_id":"schneider-electric-tm3dq16tk-modicon-tm3-discrete-output-module","title":"Schneider Electric TM3DQ16TK Modicon TM3 Discrete Output Module","description":"\u003cp\u003eThe Schneider Electric TM3DQ16TK, also cataloged as the TM3DQ16TK discrete output module, provides 16 positive-logic PNP transistor outputs for 24 VDC signal control in Modicon TM3 expansion I\/O systems. It connects to compatible Modicon M221, M241, M251, and M262 logic controllers through the expansion bus and uses HE-10 connectors for output wiring. Each output channel has a green status LED for local indication.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTM3DQ16TK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon TM3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eTaiwan (TW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16 transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic (PNP\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per transistor output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Response Time\u003c\/td\u003e\n\u003ctd\u003e450 us ON \/ 450 us OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 0.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e20 mA at 5 VDC; 10 mA at 24 VDC (specified operating values)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput-to-Internal Logic Isolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput-to-Supply Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Bus Isolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eHE-10 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Cable Length\u003c\/td\u003e\n\u003ctd\u003e5 m, unshielded cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signaling\u003c\/td\u003e\n\u003ctd\u003eOne green LED per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e21.4 x 81.3 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C horizontal; -10 to 35 deg C vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTH35-15 \/ TH35-7.5 DIN rail or panel mounting with fixing kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eModicon M221, M241, M251, M262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, cULus, UKCA, RCM, EAC, cULus HazLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611506\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e61 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePNP Transistor Output Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TM3DQ16TK switches 24 VDC field signals using 16 sourcing transistor outputs. Each channel supports a maximum output current of 100 mA, with a maximum ON\/OFF response time of 450 us. The maximum leakage current is 0.1 mA, and the maximum output voltage drop is less than 0.4 V.\u003c\/p\u003e\n\u003cp\u003eThe HE-10 output connector provides the electrical interface to field devices. The specified maximum unshielded output cable length is 5 m. Applications must remain within the per-channel current rating and the controller's output logic configuration.\u003c\/p\u003e\n\u003cp\u003eThe module uses the Modicon TM3 expansion bus to exchange data and receive internal power. Its interlocking assembly mechanism supports physical integration with compatible TM3 modules and Modicon logic controllers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Which Modicon controllers are compatible with the TM3DQ16TK?\u003c\/p\u003e\n\u003cp\u003eA: The module is listed as compatible with Modicon M221, M241, M251, and M262 controllers. Confirm the controller model, firmware, and engineering software compatibility before installation.\u003c\/p\u003e\n\u003cp\u003eQ: What are the output current and response-time limits?\u003c\/p\u003e\n\u003cp\u003eA: Each transistor output supports up to 100 mA. The maximum specified response time is 450 us for both turn-on and turn-off. The load must remain within the channel rating.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation and cable-length limits apply?\u003c\/p\u003e\n\u003cp\u003eA: The specifications list 500 VAC isolation between outputs and internal logic, 1500 VAC between outputs and supply, and 500 VAC between channels and the bus. The maximum specified output cable length is 5 m using unshielded cable.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMounting: Install the module on a TH35-15 or TH35-7.5 DIN rail compliant with IEC 60715, or use the specified panel-mounting fixing kit. Engage the interlocking mechanism with adjacent compatible modules.\u003c\/li\u003e\n\u003cli\u003ePower isolation: Disconnect control power before wiring or removing the module. Follow the controller and system manufacturer's procedures for safe installation.\u003c\/li\u003e\n\u003cli\u003eOutput wiring: Connect field loads through the HE-10 interface. Verify PNP\/source logic and confirm that each load remains within the 24 VDC and 100 mA per-channel ratings.\u003c\/li\u003e\n\u003cli\u003eCable routing: Keep output cables within the specified 5 m maximum. Route signal wiring away from high-current conductors and switching noise sources where practicable.\u003c\/li\u003e\n\u003cli\u003eGrounding and shielding: Follow the controller and machine grounding design. The specified output cable is unshielded; do not substitute shielded wiring requirements without checking the applicable installation documentation.\u003c\/li\u003e\n\u003cli\u003eEnvironmental conditions: Maintain the applicable temperature limit for the installation orientation. The enclosure provides IP20 protection, so install the module in an enclosure suitable for the site's environmental conditions.\u003c\/li\u003e\n\u003cli\u003eCommissioning: Verify bus communication, output channel assignment, load current, and the green channel status LEDs before returning the equipment to service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67666259837170,"sku":"TM3DQ16TK","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/TM3DQ16TK2.jpg?v=1791619261","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-tm3dq16tk-modicon-tm3-discrete-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}