{"product_id":"schneider-electric-tm241ce40t-modicon-m241-logic-controller","title":"Schneider Electric TM241CE40T Modicon M241 Logic Controller","description":"\u003cp\u003eConfigured for compact machine control with discrete I\/O, high-speed counting, positioning, and Ethernet communication in the Modicon M241 platform, the \u003cstrong\u003eSchneider Electric TM241CE40T\u003c\/strong\u003e (\u003cstrong\u003eM241\u003c\/strong\u003e Logic Controller) provides 40 integrated I\/O points with 24 VDC transistor outputs and multiple communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTM241CE40T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24, including 8 fast inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e16 transistor outputs, including 4 fast outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic, source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Output Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Frequency\u003c\/td\u003e\n\u003ctd\u003e20 kHz PWM, 100 kHz PLS, 1 kHz standard output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Input Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to 200 kHz HSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Outputs\u003c\/td\u003e\n\u003ctd\u003e4 PTO outputs, up to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory RAM\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Flash\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional SD Card\u003c\/td\u003e\n\u003ctd\u003eUp to 16 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX, RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, EtherNet\/IP, OPC UA, FTP, SNMP and web services\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface 1\u003c\/td\u003e\n\u003ctd\u003eRJ45, RS232\/RS485, non-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface 2\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block, RS485, non-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eMini B USB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e1.2-115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e32.6-40.4 W with maximum I\/O expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 x 95 x 90 mm (W x D x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 deg C vertical; -10 to 55 deg C horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTH35-15 rail, TH35-7.5 rail, plate or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Local I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003e7 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Remote I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003e14 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Common Current\u003c\/td\u003e\n\u003ctd\u003e2 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e50 us standard; \u0026lt;= 2 us fast inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 34 us turn-on; \u0026lt;= 250 us turn-off standard outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003e500 VAC between specified supply, logic, input and output circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eUp to 1 kV common-mode and 0.5 kV differential-mode values depending on circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, cULus, RCM, UKCA, DNV-GL, ABS, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet, I\/O Density and Firmware Functions\u003c\/h3\u003e\n\u003cp\u003eThe TM241CE40T combines 40 integrated discrete I\/O points with Ethernet and serial communication interfaces. The 24 inputs include 8 fast inputs supporting high-speed counting functions up to 200 kHz. Four transistor outputs provide fast output functions, with PWM operation up to 20 kHz and PLS operation up to 100 kHz.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface operates at 10\/100 Mbit\/s and supports Modbus TCP client\/server functions and EtherNet\/IP scanner and target functions. The controller also provides firmware updating through its Ethernet service set. Application memory consists of 8 MB program memory, 64 MB system RAM, and 128 MB built-in flash for user-program backup.\u003c\/p\u003e\n\u003cp\u003eThe controller supports EcoStruxure Machine Expert for application programming. Its integrated Ethernet services include DHCP, SNMP, FTP, web server, OPC UA server, SQL client, and Modbus TCP and EtherNet\/IP communication functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What supply voltage does the TM241CE40T require?\u003cbr\u003eA: The controller is rated for 24 VDC, with a specified supply range of 20.4-28.8 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Are the integrated Ethernet and serial interfaces electrically isolated?\u003cbr\u003eA: The Ethernet interface is provided through an RJ45 connection. Both integrated serial links are specified as non-isolated.\u003c\/p\u003e\n\u003cp\u003eQ: What are the fast I\/O limits?\u003cbr\u003eA: Eight fast inputs support HSC operation up to 200 kHz. Four fast transistor outputs support PWM up to 20 kHz and PLS up to 100 kHz.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller on a TH35-15 or TH35-7.5 DIN rail according to IEC 60715, or use the specified plate or panel mounting method.\u003c\/li\u003e\n\u003cli\u003eSupply the controller within the specified 20.4-28.8 VDC range and observe the 50 A stated inrush current when sizing the power supply and protective devices.\u003c\/li\u003e\n\u003cli\u003eUse the removable screw terminal blocks for 24 VDC power and discrete I\/O connections. The specified terminal pitch is 5.08 mm.\u003c\/li\u003e\n\u003cli\u003eKeep input and output wiring within the specified cable-distance limits. Standard input and output wiring is specified up to 50 m with unshielded cable.\u003c\/li\u003e\n\u003cli\u003eFor fast signals, observe the shorter specified limits: shielded fast-input wiring is limited to 10 m and shielded fast-output wiring to 3 m.\u003c\/li\u003e\n\u003cli\u003eRoute fast I\/O and communication cables separately from high-current or high-noise conductors where practical to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the machine grounding design and applicable EMC requirements. Avoid creating unintended ground loops through multiple shield termination paths.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified environmental limits of -10 to 50 deg C for vertical installation or -10 to 55 deg C for horizontal installation, with non-condensing humidity.\u003c\/li\u003e\n\u003cli\u003eKeep the controller within its IP20 installation environment and use the protective cover where specified.\u003c\/li\u003e\n\u003cli\u003eFor Ethernet commissioning, verify the assigned IP configuration and communication parameters before enabling Modbus TCP or EtherNet\/IP data exchange.\u003c\/li\u003e\n\u003cli\u003eWhen using high-speed inputs or outputs, verify signal wiring, polarity, load characteristics, and configured frequency before applying the machine power stage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67593951445234,"sku":"TM241CE40T","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/TM241CE40T2.jpg?v=1790675070","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-tm241ce40t-modicon-m241-logic-controller","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}