{"product_id":"schneider-electric-tm241ce40r-modicon-m241-logic-controller","title":"Schneider Electric TM241CE40R Modicon M241 Logic Controller","description":"\u003cp\u003eConfigured for discrete I\/O processing and Ethernet-based machine communication in the Modicon M241 platform, the \u003cstrong\u003eSchneider Electric TM241CE40R\u003c\/strong\u003e (\u003cstrong\u003eTM241CE40R\u003c\/strong\u003e logic controller) provides direct physical and electrical control through 40 integrated I\/O points, relay and transistor outputs, serial interfaces, USB, and 10\/100 Mbit\/s Ethernet.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTM241CE40R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 x 95 x 90 mm (W x D x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 deg C vertical; -10 to 55 deg C horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24 standard inputs, including 8 fast inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Current\u003c\/td\u003e\n\u003ctd\u003e7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e12 relay, 4 transistor, including 4 fast outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5 to 125 VDC; 5 to 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Output Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Fast Output Frequency\u003c\/td\u003e\n\u003ctd\u003e20 kHz PWM; 100 kHz PLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counter Inputs\u003c\/td\u003e\n\u003ctd\u003e4 at up to 200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Outputs\u003c\/td\u003e\n\u003ctd\u003e4 PTO channels, up to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e64 MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Flash\u003c\/td\u003e\n\u003ctd\u003e128 MB for user program backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional SD Card\u003c\/td\u003e\n\u003ctd\u003eUp to 16 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, EtherNet\/IP, OPC UA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Link 1\u003c\/td\u003e\n\u003ctd\u003eRJ45, RS232\/RS485, non-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Link 2\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block, RS485, non-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eMini-B USB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e1.2 to 115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003eUp to 7 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003eUp to 14 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTH35-15 or TH35-7.5 DIN rail; panel mounting with fixing kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003e500 VAC between supply and internal logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eUp to 2 kV depending on circuit and test mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, cULus, RCM, UKCA, DNV-GL, ABS, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet Communication and I\/O Scaling\u003c\/h3\u003e\n\u003cp\u003eThe TM241CE40R integrates 40 discrete I\/O points with 24 inputs and 16 outputs. The output section combines relay and transistor circuits, allowing separate handling of switching loads and high-speed pulse functions. Four fast inputs support high-speed counter operation up to 200 kHz, while four PTO channels support positioning signals up to 100 kHz.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface operates at 10\/100 Mbit\/s and provides Modbus TCP and EtherNet\/IP functions. The controller supports Modbus TCP client and server functions, EtherNet\/IP target and originator I\/O scanning, FTP, SNMP, DHCP, firmware updating, web services, and OPC UA server functions. Up to 64 Modbus TCP devices and 16 EtherNet\/IP devices are specified.\u003c\/p\u003e\n\u003cp\u003eSerial communication uses two non-isolated links. Serial Link 1 provides selectable RS232\/RS485 through an RJ45 connector, while Serial Link 2 provides RS485 through a removable screw terminal block. Modbus master\/slave communication is supported at up to 115.2 kbit\/s.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the I\/O arrangement of the TM241CE40R?\u003c\/p\u003e\n\u003cp\u003eA: The controller has 40 integrated discrete I\/O points: 24 inputs and 16 outputs. The outputs comprise 12 relay outputs and 4 transistor outputs, with the transistor section providing fast-output functions.\u003c\/p\u003e\n\u003cp\u003eQ: What Ethernet protocols are supported?\u003c\/p\u003e\n\u003cp\u003eA: The integrated Ethernet port supports Modbus TCP and EtherNet\/IP, including Modbus TCP client\/server functions and EtherNet\/IP target\/originator I\/O scanning. OPC UA server functionality is also specified.\u003c\/p\u003e\n\u003cp\u003eQ: Can the controller be expanded with additional I\/O?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied specifications state support for up to 7 local I\/O expansion modules and up to 14 remote I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller on a TH35-15 or TH35-7.5 DIN rail according to IEC 60715, or use the specified panel fixing method.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified installation orientation when applying the corresponding operating temperature limit.\u003c\/li\u003e\n\u003cli\u003eKeep input, output, Ethernet, serial, and power wiring physically organized to reduce coupling between high-current switching circuits and communication wiring.\u003c\/li\u003e\n\u003cli\u003eUse the specified cable-distance limits. Standard input and output wiring is specified up to 50 m, while shielded fast-input wiring is limited to 10 m and shielded fast-output wiring to 3 m.\u003c\/li\u003e\n\u003cli\u003eConnect the removable terminal blocks securely and maintain the specified 5.08 mm terminal pitch arrangement.\u003c\/li\u003e\n\u003cli\u003eFast I\/O circuits should use wiring practices appropriate to pulse and high-speed counter signals to limit electrical noise and signal distortion.\u003c\/li\u003e\n\u003cli\u003eEthernet and serial communication cables should be routed separately from high-energy switching conductors where practical.\u003c\/li\u003e\n\u003cli\u003eApply cable shielding and grounding according to the machine electrical design and the applicable installation standards.\u003c\/li\u003e\n\u003cli\u003eVerify the 100 to 240 VAC rated supply and the 85 to 264 VAC supply limits before energizing the controller.\u003c\/li\u003e\n\u003cli\u003eKeep the protective cover in place to maintain the stated IP20 protection condition.\u003c\/li\u003e\n\u003cli\u003eCheck the PWR, RUN, ERR, I\/O, SD, BAT, SL1, SL2, TM4, I\/O channel, and Ethernet status indicators during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67593456386290,"sku":"TM241CE40R","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/TM241CE40R2.jpg?v=1790674825","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-tm241ce40r-modicon-m241-logic-controller","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}