{"product_id":"schneider-electric-tm208lda24drn-modicon-m208-compact-plc-base-unit","title":"Schneider Electric TM208LDA24DRN Modicon M208 Compact PLC Base Unit","description":"\u003cp\u003eConfigured for discrete I\/O control in the Modicon M208 platform, the \u003cstrong\u003eSchneider Electric TM208LDA24DRN\u003c\/strong\u003e (\u003cstrong\u003eTM208LDA24DRN\u003c\/strong\u003e Compact PLC Base Unit) provides 14 digital inputs and 10 relay outputs with 100-240 VAC supply and DIN rail or panel mounting.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTM208LDA24DRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon M208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCompact PLC \/ CPU Base Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 W at 100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Discrete I\/O\u003c\/td\u003e\n\u003ctd\u003e24 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e14 x 24 VDC, sink\/source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 ms, turn-on \/ turn-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail \/ panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC I\/O and Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe TM208LDA24DRN integrates discrete I\/O directly into the compact controller base. The 14 digital inputs accept 24 VDC signals and support sink\/source configurations, while the 10 relay outputs provide electrically switched discrete output channels. The approximately 2 ms input response time applies to both turn-on and turn-off response as specified.\u003c\/p\u003e\n\u003cp\u003eFor Modicon M208 installations, I\/O wiring should be separated from higher-voltage conductors and routed according to the cabinet wiring design. The supplied data does not specify a backplane communication velocity, expansion-bus timing, or firmware compatibility matrix, so these parameters should be verified against the applicable M208 hardware and firmware documentation before configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What supply voltage does the TM208LDA24DRN require?\u003cbr\u003eA: The rated supply is 100-240 VAC, with a specified operating limit of 85-264 VAC.\u003c\/p\u003e\n\u003cp\u003eQ: How many discrete I\/O points are integrated?\u003cbr\u003eA: The unit has 24 discrete I\/O points: 14 digital inputs and 10 relay outputs.\u003c\/p\u003e\n\u003cp\u003eQ: Can the controller be mounted on a DIN rail?\u003cbr\u003eA: Yes. The supplied specifications identify 35 mm DIN rail mounting and panel mounting.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the controller on a compatible 35 mm DIN rail or suitable panel surface.\u003c\/li\u003e\n\u003cli\u003eMaintain physical separation between low-voltage signal wiring and higher-voltage AC wiring to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eRoute the 24 VDC input wiring according to the sink\/source configuration used by the connected field devices.\u003c\/li\u003e\n\u003cli\u003eWire relay outputs according to the load type and applicable cabinet protection requirements.\u003c\/li\u003e\n\u003cli\u003eConnect protective and functional grounding in accordance with the control cabinet design and applicable electrical standards.\u003c\/li\u003e\n\u003cli\u003eKeep signal cables away from high-current switching conductors, contactors, and drive power cables where practical.\u003c\/li\u003e\n\u003cli\u003eVerify the actual supply voltage before energizing the 100-240 VAC power input.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the specified environmental range of 0 to 55 deg C during operation.\u003c\/li\u003e\n\u003cli\u003eThe IP20 rating does not provide protection against direct water exposure; installation should therefore be inside an appropriately protected enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67583619334386,"sku":"TM208LDA24DRN","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/TM208LDA24DRN.jpg?v=1790589470","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-tm208lda24drn-modicon-m208-compact-plc-base-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}