{"product_id":"schneider-electric-mnb1000-15-remote-i-o-expansion-module","title":"Schneider Electric MNB1000-15 Remote I\/O Expansion Module","description":"\u003cp\u003eConfigured for remote input and output point expansion in the TAC I\/A Series MicroNet BACnet Plant Controller network, the \u003cstrong\u003eSchneider Electric MNB1000-15\u003c\/strong\u003e (\u003cstrong\u003eMNB1000-15\u003c\/strong\u003e Remote I\/O Expansion Module) provides direct physical signal acquisition and output execution through 15 dedicated I\/O channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMNB1000-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTAC I\/A Series MicroNet BACnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 178 mm x 56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e16 VA at 24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e20.4 to 30 VAC, 50\/60 Hz, nominal 24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e15 points total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal Inputs\u003c\/td\u003e\n\u003ctd\u003e6 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal Outputs\u003c\/td\u003e\n\u003ctd\u003e3 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e6 Triac outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Bus\u003c\/td\u003e\n\u003ctd\u003eDedicated remote I\/O bus with DIP-switch addressing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mount \/ wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e10k Ohm thermistor, RTD, 0-5 VDC, 0-20 mA, dry contact, pulse input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal Output Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA and 0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTriac Output Rating\u003c\/td\u003e\n\u003ctd\u003e12 VA at 24 VAC, 50\/60 Hz, individually isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 916, FCC Part 15 Class A, CE Mark, C-Tick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe MNB1000-15 performs local point expansion through the TAC I\/A Series MicroNet BACnet architecture. The module increases controller capacity by adding six Universal Inputs, three Universal Outputs, and six Triac Digital Outputs. A single MNB-1000 controller can support up to eight MNB1000-15 expansion modules, providing a maximum system capacity of 152 I\/O points.\u003c\/p\u003e\n\u003cp\u003eThe hardware uses removable electronics with screw terminal connections for field wiring access. DIP-switch addressing defines the remote I\/O position, while LED indicators provide status information for power, communication, and output activity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical signals can the MNB1000-15 Universal Inputs accept?\u003cbr\u003eA: The six Universal Inputs support thermistor signals, RTD inputs, 0-5 VDC analog voltage, 0-20 mA analog current with external shunt resistance, dry contact switching, and pulse input signals.\u003c\/p\u003e\n\u003cp\u003eQ: How are the Triac Digital Outputs electrically configured?\u003cbr\u003eA: The six Triac Digital Outputs provide individually isolated outputs rated at 12 VA at 24 VAC, 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003eQ: What installation interface is provided for field wiring?\u003cbr\u003eA: The module uses fixed and removable screw terminals designed for AWG #14 to #18 wiring connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the MNB1000-15 on a suitable panel or wall-mounted surface according to the MicroNet BACnet controller installation requirements. Verify the 24 VAC power source polarity and wiring separation before energizing the module.\u003c\/p\u003e\n\u003cp\u003eUse dedicated field wiring paths for input signals, analog outputs, and Triac outputs to reduce electrical interference. Shielded cables should be applied where signal noise conditions require additional protection, with cable shields terminated according to site grounding practices.\u003c\/p\u003e\n\u003cp\u003eConfirm DIP-switch addressing before connecting the remote I\/O bus. Ensure removable terminal blocks are fully seated and verify LED status indicators after power application.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50518470525170,"sku":"MNB1000-15","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/MNB1000-152.jpg?v=1790133966","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-mnb1000-15-remote-i-o-expansion-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}