{"product_id":"schneider-electric-mnb-cntlr-1000-bacnet-ms-tp-plant-controller","title":"Schneider Electric MNB-CNTLR-1000 BACnet MS\/TP Plant Controller","description":"\u003cp\u003eConfigured for BACnet MS\/TP plant control execution in the Schneider Electric I\/A Series MicroNet building automation network, the \u003cstrong\u003eSchneider Electric MNB-CNTLR-1000\u003c\/strong\u003e (\u003cstrong\u003eMNB-1000\u003c\/strong\u003e BACnet Plant Controller) provides direct physical and electrical control of HVAC field I\/O signals, relay outputs, and RS-485 network communication.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMNB-CNTLR-1000 \/ MNB-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric (TAC \/ Invensys I\/A Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.95 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 30 VA to 50 VA depending on expanded I\/O loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eBACnet MS\/TP Plant Controller \/ BACnet Building Controller (B-BC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eBACnet MS\/TP over RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Baud Rates\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps, 19.2 kbps, 38.4 kbps, 76.8 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VAC +\/-20%, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels, supporting 0-10 VDC, 0-20 mA, thermistor, and resistance signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels, dry contact and pulse counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels, 0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8 relay outputs, Form A, 24 VAC \/ 30 VDC, 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Expansion\u003c\/td\u003e\n\u003ctd\u003eSupports MNB-Ix series expansion modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit microprocessor with flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eIntegrated RTC with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Environment\u003c\/td\u003e\n\u003ctd\u003eWorkPlace Tech Tool (WPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 1 \/ IP20 equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mount or DIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 916, CE, FCC Part 15 Class A, BTL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBACnet MS\/TP Network and Plant Control Functions\u003c\/h3\u003e\n\u003cp\u003eThe MNB-1000 communicates through BACnet MS\/TP using an RS-485 physical interface with selectable baud rates for network integration. The controller executes local control sequences, scheduling functions, trend storage, and logic operations through WorkPlace Tech Tool programming.\u003c\/p\u003e\n\u003cp\u003eThe controller handles direct field signal processing through universal inputs, analog outputs, digital inputs, and relay outputs. The onboard processor and non-volatile flash memory maintain application programs, configuration parameters, and network settings during power interruption.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interface is provided by the MNB-CNTLR-1000?\u003cbr\u003eA: The controller uses a BACnet MS\/TP communication interface based on RS-485 physical signaling.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MNB-1000 operate without a supervisory controller?\u003cbr\u003eA: Yes. The controller supports standalone execution of programmed logic, schedules, trends, and local control functions.\u003c\/p\u003e\n\u003cp\u003eQ: What type of I\/O expansion is supported by the controller?\u003cbr\u003eA: The MNB-1000 supports additional I\/O capacity through MNB-Ix series expansion modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the controller on a suitable panel surface or DIN rail location with sufficient clearance for field wiring access. Separate RS-485 communication wiring from high-voltage power conductors to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eConnect the 24 VAC supply according to the controller wiring requirements and verify polarity where applicable. Use shielded communication cable for BACnet MS\/TP networks when required by site wiring practices, with cable shielding connected according to the installation grounding standard.\u003c\/p\u003e\n\u003cp\u003eTerminate RS-485 network segments according to BACnet MS\/TP wiring rules. Verify input signal types before connecting field devices to universal input channels to prevent incorrect scaling or signal interpretation.\u003c\/p\u003e\n\u003cp\u003eConfigure application logic, network parameters, and I\/O assignments through WorkPlace Tech Tool after physical installation and wiring verification.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50518565552370,"sku":"MNB-CNTLR-1000","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/MNB-CNTLR-10002.jpg?v=1790134327","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-mnb-cntlr-1000-bacnet-ms-tp-plant-controller","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}