{"product_id":"schneider-electric-metsepm5560-powerlogic-pm5000-power-meter","title":"Schneider Electric METSEPM5560 PowerLogic PM5000 Power Meter","description":"\u003cp\u003eConfigured for multi-parameter electrical measurement in PowerLogic PM5000 systems, the \u003cstrong\u003eSchneider Electric METSEPM5560\u003c\/strong\u003e (\u003cstrong\u003ePM5560\u003c\/strong\u003e power meter) provides direct measurement of voltage, current, frequency, power factor, energy, active and reactive power, with harmonic analysis through the 63rd harmonic and Ethernet\/RS485 communications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMETSEPM5560\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003ePM5560\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePowerLogic PM5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e96 mm W x 72 mm D x 96 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFlush-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eBacklit LCD, 128 x 128 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e16 VA at 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e90 to 528 VAC, 45 to 65 Hz; 100 to 300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Rated Current\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Voltage\u003c\/td\u003e\n\u003ctd\u003e20 to 400 VAC phase-neutral; 20 to 828 VAC phase-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement Range\u003c\/td\u003e\n\u003ctd\u003e50 to 10000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45 to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd\u003eClass 0.2S active energy, IEC 62053-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e128 samples\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Measurement\u003c\/td\u003e\n\u003ctd\u003eUp to 63rd harmonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e1.1 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, ASCII, JBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP, BACnet\/IP, DNP3 over Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connection\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45, daisy-chain capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb Services\u003c\/td\u003e\n\u003ctd\u003eWeb server, real-time data viewing, diagnostics, alarm e-mail notification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP54 front\/display, IP30 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 % RH, non-condensing at 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Ethernet and Power Quality Measurement\u003c\/h3\u003e\n\u003cp\u003eThe METSEPM5560 combines electrical metering with Ethernet and serial communications. The RS485 interface supports two-wire Modbus RTU, ASCII and JBUS operation, while the Ethernet interfaces support Modbus TCP\/IP, BACnet\/IP and DNP3 over Ethernet. Ethernet\/serial gateway functionality permits communication between the serial and Ethernet sides.\u003c\/p\u003e\n\u003cp\u003ePower-quality measurement extends through the 63rd harmonic. The meter samples at 128 samples\/cycle and measures voltage, current, frequency, power factor, energy, active power and reactive power. Neutral current is measured directly, while ground current can be calculated. Four digital inputs provide WAGES monitoring functions, and two digital outputs provide control signaling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What supply voltage can the METSEPM5560 accept?\u003c\/strong\u003e\u003cbr\u003eA: The specified supply range is 90 to 528 VAC at 45 to 65 Hz or 100 to 300 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication interfaces are provided?\u003c\/strong\u003e\u003cbr\u003eA: The meter provides an RS485 interface and two RJ45 Ethernet ports. Supported protocols include Modbus RTU, Modbus ASCII, JBUS, Modbus TCP\/IP, BACnet\/IP and DNP3 over Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What electrical configurations are supported?\u003c\/strong\u003e\u003cbr\u003eA: The meter supports single-phase plus neutral, three-phase, and three-phase plus neutral configurations, with 1 A or 5 A line-rated current inputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the meter as a flush-mounted device using the specified panel mounting arrangement.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between voltage\/current measurement wiring and communication wiring to reduce conducted interference.\u003c\/li\u003e\n\u003cli\u003eConnect current transformer circuits according to the applicable current-input wiring arrangement and verify polarity before energization.\u003c\/li\u003e\n\u003cli\u003eUse the RS485 two-wire connection with appropriate communication cable practices and termination according to the network topology.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet cables separately from high-current or high-noise conductors where practical.\u003c\/li\u003e\n\u003cli\u003eBond cable shields according to the plant grounding and EMC design. Avoid creating unintended ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify the measurement voltage, CT secondary rating, phase sequence and neutral connection before applying operating voltage.\u003c\/li\u003e\n\u003cli\u003eConfirm the required Modbus, BACnet or DNP3 addressing and communication parameters before connecting the meter to the control network.\u003c\/li\u003e\n\u003cli\u003eKeep the rear of the meter within the specified IP30 protection conditions and the front panel within its IP54 protection conditions.\u003c\/li\u003e\n\u003cli\u003eVerify ambient temperature and humidity remain within the specified operating limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50135124672754,"sku":"PM5560","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/PM55602.jpg?v=1789974501","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-metsepm5560-powerlogic-pm5000-power-meter","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}