{"product_id":"schneider-electric-ltmr100ebd-tesys-t-motor-controller","title":"Schneider Electric LTMR100EBD TeSys T Motor Controller","description":"\u003cp\u003eConfigured for motor monitoring, protection, and control execution in TeSys T motor management systems, the \u003cstrong\u003eSchneider Electric LTMR100EBD\u003c\/strong\u003e (\u003cstrong\u003eLTMR100EBD\u003c\/strong\u003e Motor Controller) provides direct physical and electrical management of current measurement, logic I\/O, and Ethernet communication functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLTMR100EBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eTeSys T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Current Range\u003c\/td\u003e\n\u003ctd\u003e5 to 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e56 to 127 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet IEEE 802.3, RJ45, 10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Inputs\u003c\/td\u003e\n\u003ctd\u003e6 discrete inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Outputs\u003c\/td\u003e\n\u003ctd\u003e3 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Signal Output\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC relay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd\u003e3 phase current measurement through integrated current transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Current Measurement\u003c\/td\u003e\n\u003ctd\u003eInternal or external ground sensor input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement\u003c\/td\u003e\n\u003ctd\u003eSupported through optional expansion module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Measurement\u003c\/td\u003e\n\u003ctd\u003eSupported through optional expansion module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV for current\/voltage circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Withstand\u003c\/td\u003e\n\u003ctd\u003e100 kA according to EN\/IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e91 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e122.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC supply, 56 to 127 mA current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eLocked rotor, overload, thermal overload, earth leakage, phase failure, phase unbalance, load fluctuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and Modbus TCP Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe LTMR100EBD integrates Ethernet communication through an RJ45 interface using EtherNet\/IP and Modbus TCP protocols. The controller exchanges motor operating data, diagnostic information, fault records, and control commands with automation systems through Ethernet IEEE 802.3 communication.\u003c\/p\u003e\n\u003cp\u003eThe TeSys T controller supports deterministic data transfer for motor management functions, including current monitoring, trip context information, event recording, operating time counters, and motor control command logging.\u003c\/p\u003e\n\u003cp\u003eFirmware compatibility is managed through the TeSys T firmware package supporting Ethernet, Profibus, CANopen, DeviceNet, and Modbus communication variants.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What motor parameters are measured by the LTMR100EBD?\u003cbr\u003eA: The controller measures phase currents I1, I2, and I3 RMS, average current, earth fault current, temperature, imbalance current, and related motor operating conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Does the LTMR100EBD provide direct Ethernet communication?\u003cbr\u003eA: Yes. The controller provides EtherNet\/IP and Modbus TCP communication through an Ethernet IEEE 802.3 RJ45 interface.\u003c\/p\u003e\n\u003cp\u003eQ: What type of logic interfaces are available on this controller?\u003cbr\u003eA: The unit provides 6 logic inputs, 3 relay logic outputs, and a dedicated relay output for fault signaling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the LTMR100EBD on a suitable control panel mounting structure with sufficient clearance for terminal access and Ethernet cable routing.\u003c\/p\u003e\n\u003cp\u003eConnect the 24 VDC supply according to the specified polarity requirements. Maintain separation between communication wiring, motor power conductors, and high-current switching circuits to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eUse shielded Ethernet cabling where required by the installation environment and connect cable shields according to the plant grounding practice. Verify terminal tightening torque and conductor preparation before commissioning.\u003c\/p\u003e\n\u003cp\u003eCurrent sensing wiring must follow the motor circuit configuration requirements. Confirm phase conductor routing through the integrated current transformers and verify earth fault sensor connections before applying operating voltage.\u003c\/p\u003e\n\u003cp\u003eThe LTMR100EBD product is scheduled for discontinuation on Sep 30, 2026, with end-of-service on Jan 31, 2027. Recommended replacement groups include TeSys Tera components such as LTMTEBD with compatible current sensor modules.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50111915393266,"sku":"LTMR100EBD","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/LTMR100EBD2.jpg?v=1789716061","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-ltmr100ebd-tesys-t-motor-controller","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}