{"product_id":"schneider-electric-hmigto5315-harmony-gto-touchscreen-panel","title":"Schneider Electric HMIGTO5315 Harmony GTO Touchscreen Panel","description":"\u003cp\u003eConfigured for touchscreen visualization, operator input, and serial\/Ethernet data exchange in Harmony GTO systems, the \u003cstrong\u003eSchneider Electric HMIGTO5315\u003c\/strong\u003e (\u003cstrong\u003eHMIGTO\u003c\/strong\u003e touchscreen panel) provides direct display and control functions through a 10.4 inch TFT LCD, resistive touch panel, RS232C, RS485, and Ethernet interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHMIGTO5315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTouchscreen Operator Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eHarmony GTO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e10.4 inch color TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels VGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Colors\u003c\/td\u003e\n\u003ctd\u003e65536\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Technology\u003c\/td\u003e\n\u003ctd\u003eResistive film, 1024 x 1024 touch zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Panel Life\u003c\/td\u003e\n\u003ctd\u003e1000000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e96 MB Flash EPROM; 512 KB internal SRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eSD\/SDHC card, up to 32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eARM926EJ-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e19.2 to 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e17 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption, Backlight Off\u003c\/td\u003e\n\u003ctd\u003e7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption, Backlight Dimmed\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eRS232C, 2400 to 115200 bps; RS485, 2400 to 115200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSiemens MPI Interface\u003c\/td\u003e\n\u003ctd\u003eRS485, 187.5 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX, IEEE 802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Interfaces\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Type A and USB 2.0 Mini-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eModbus, Uni-TE, Modbus Plus, FIPWAY, Modbus TCP and listed third-party protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFlush mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e316.5 x 258.5 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90 percent, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eBelow 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Protection\u003c\/td\u003e\n\u003ctd\u003eIP66K; NEMA 4X for indoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61000-6-2, UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eC-tick, cULus, CE, KCC, UKCA, UKEX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet and Serial Communication\u003c\/h3\u003e\n\u003cp\u003eThe HMIGTO5315 provides one Ethernet RJ45 interface supporting 10BASE-T\/100BASE-TX and IEEE 802.3 communication. Modbus TCP is available through the Ethernet interface. The serial architecture includes one RS232C port and one RS485 port, with configurable communication rates within the specified ranges. The RS485 interface also supports Siemens MPI operation at 187.5 kbps.\u003c\/p\u003e\n\u003cp\u003eThe panel supports Modbus and other listed Schneider Electric protocols, together with specified third-party protocols for Mitsubishi, Omron, Rockwell Automation Allen-Bradley, and Siemens systems. Communication selection must match the protocol configuration of the connected controller.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What supply voltage is required by the HMIGTO5315?\u003cbr\u003eA: The rated supply is 24 VDC, with an allowable supply range of 19.2 to 28.8 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are integrated?\u003cbr\u003eA: The panel provides RS232C, RS485, Ethernet RJ45, USB 2.0 Type A, and USB 2.0 Mini-B interfaces.\u003c\/p\u003e\n\u003cp\u003eQ: Can the HMIGTO5315 operate in a stainless steel front-panel installation?\u003cbr\u003eA: Yes. The front material is stainless steel 304, and the specified front protection is IP66K. The mounting method is flush mounting using 8 nuts or 4 L brackets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the HMIGTO5315 by flush mounting the panel in a mechanically stable enclosure or control surface. Maintain the specified mounting arrangement and ensure that the front sealing surface is clean and undamaged before installation.\u003c\/p\u003e\n\u003cp\u003eSupply the unit from a regulated 24 VDC source within the specified 19.2 to 28.8 VDC range. Route DC power wiring separately from high-current switching conductors where practical. Connect protective grounding according to the enclosure and site electrical design.\u003c\/p\u003e\n\u003cp\u003eFor RS232C and RS485 wiring, use cabling appropriate to the selected communication interface. Keep communication wiring separated from high-voltage and high-current conductors to reduce electromagnetic coupling. For RS485 networks, observe the network topology and termination requirements defined by the selected protocol.\u003c\/p\u003e\n\u003cp\u003eUse shielded Ethernet or serial cabling where required by the installation environment. Apply cable shielding and grounding according to the controller, communication equipment, and site EMC requirements.\u003c\/p\u003e\n\u003cp\u003eThe front panel provides IP66K protection when installed according to the manufacturer's mounting and sealing requirements. The rear side remains IP20 and should therefore be protected from direct exposure to liquids, conductive contamination, and unsuitable mechanical contact.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50103507353842,"sku":"HMIGTO5315","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/HMIGTO53152.jpg?v=1789631996","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-hmigto5315-harmony-gto-touchscreen-panel","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}