{"product_id":"schneider-electric-egx150-link-150-ethernet-gateway","title":"Schneider Electric EGX150 Link 150 Ethernet Gateway","description":"\u003cp\u003eConfigured for serial-to-Ethernet protocol conversion in the Enerlin'X Link platform, the \u003cstrong\u003eSchneider Electric EGX150\u003c\/strong\u003e (\u003cstrong\u003eEGX150 Link 150 Ethernet Gateway\u003c\/strong\u003e) provides direct communication between Modbus serial devices and Ethernet networks through 24 VDC external supply or IEEE 802.3af PoE.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEGX150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEnerlin'X Link 150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eGateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2 Ethernet ports; RJ45 RS232; RJ45 RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Communication\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s, Modbus TCP\/IP, FTP, HTTP, SNMP, PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication\u003c\/td\u003e\n\u003ctd\u003eRS232 \/ RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, Modbus ASCII, JBUS, PowerLogic (SY\/MAX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Baud Rate\u003c\/td\u003e\n\u003ctd\u003e2400 to 57600 bauds depending on protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply\u003c\/td\u003e\n\u003ctd\u003e19.2-26.4 VDC, less than 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Supply\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3af, Class 3, 15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e130 mA at 24 VDC; 65 mA via PoE at 20 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W maximum via PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port Isolation\u003c\/td\u003e\n\u003ctd\u003e6 kV for Ethernet Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port Isolation\u003c\/td\u003e\n\u003ctd\u003e2.5 kV for Modbus serial communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eClip-on, 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e71 mm W x 105 mm H x 72 mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e175 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% without condensation at 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP40 front panel in enclosure, IP30 casing, IP20 terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb Service\u003c\/td\u003e\n\u003ctd\u003eWeb server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signaling\u003c\/td\u003e\n\u003ctd\u003eEthernet activity, module status, network status, RS232 and RS485 communication LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003ecULus, FCC Class A, CE, RCM, UL, cUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet and Protocol Conversion\u003c\/h3\u003e\n\u003cp\u003eEGX150 provides serial-to-Ethernet communication for Modbus RTU, Modbus ASCII, JBUS and PowerLogic (SY\/MAX) devices. Ethernet communication supports Modbus TCP\/IP at 10\/100 Mbit\/s, with daisy-chain operation specified for the Ethernet Modbus TCP\/IP interface. RS232 and RS485 interfaces support master and slave configurations according to the selected serial protocol.\u003c\/p\u003e\n\u003cp\u003eThe gateway can receive operating power from a 19.2-26.4 VDC external source or through IEEE 802.3af PoE. The two Ethernet ports provide separate Ethernet activity indication, while dedicated LEDs indicate module and network communication status.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What serial interfaces are available on the EGX150?\u003c\/p\u003e\n\u003cp\u003eA: The EGX150 provides RJ45 RS232 and RJ45 RS485 interfaces for Modbus RTU, Modbus ASCII, JBUS and PowerLogic (SY\/MAX) serial communication.\u003c\/p\u003e\n\u003cp\u003eQ: What power sources can the EGX150 use?\u003c\/p\u003e\n\u003cp\u003eA: The gateway accepts an external 19.2-26.4 VDC supply or IEEE 802.3af PoE. PoE operation is specified at 15 W maximum.\u003c\/p\u003e\n\u003cp\u003eQ: Can the EGX150 be mounted on a DIN rail?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The device uses clip-on mounting on a 35 mm DIN rail.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the EGX150 on a 35 mm DIN rail inside an enclosure with adequate clearance for the RJ45 communication connectors and power terminals.\u003c\/p\u003e\n\u003cp\u003eConnect the external supply to the designated power terminal and observe the specified 19.2-26.4 VDC input range. If PoE is used, connect the Ethernet interface to a compatible IEEE 802.3af power source.\u003c\/p\u003e\n\u003cp\u003eRoute RS232 and RS485 communication wiring separately from high-voltage power and high-current switching conductors where practical. Maintain the intended RS485 wiring topology and apply the required signal reference and shield termination practices for the installation environment.\u003c\/p\u003e\n\u003cp\u003eVerify Ethernet link activity, module status, network status, and serial communication LEDs after energization. Confirm the selected serial protocol, baud rate, parity, and master\/slave configuration before placing the gateway into service.\u003c\/p\u003e\n\u003cp\u003eEGX150 is discontinued and reached its stated end-of-service date on December 31, 2024. Schneider Electric identifies PAS600 and PAS600L as recommended replacement products; application and interface requirements should be checked before substitution.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50125539246322,"sku":"EGX150","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/EGX1502.jpg?v=1789897963","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-egx150-link-150-ethernet-gateway","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}