{"product_id":"schneider-electric-bmxdra1605h-modicon-x80-discrete-output-module","title":"Schneider Electric BMXDRA1605H Modicon X80 Discrete Output Module","description":"\u003cp\u003eConfigured for switching discrete field loads in Modicon X80 systems, the \u003cstrong\u003eSchneider Electric BMXDRA1605H\u003c\/strong\u003e (\u003cstrong\u003eBMXDRA1605H\u003c\/strong\u003e discrete output module) provides 16 positive-logic relay outputs for AC and DC loads. The module supports output voltage ranges of 19-30 VDC and 19-264 VAC, with output activation below 8 ms and deactivation below 10 ms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDRA1605H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e16 NO relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e19-30 VDC; 19-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC; 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Switching Current\u003c\/td\u003e\n\u003ctd\u003e1 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8 ms activation; \u0026lt; 10 ms deactivation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e100000, 300000, 50000, 7000 cycles, depending on load conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e79 mA at 3.3 VDC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 Mohm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e2000 VAC, 50\/60 Hz, 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% at 55 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Classes\u003c\/td\u003e\n\u003ctd\u003eGas Gx, gas 3C4, dust 3S4, sand 3S4, salt level 2, mold 3B2, fungal spore 3B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eIECEx, ATEX, EAC, Merchant Navy, CSA, RCM, CE, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3595864025803\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon X80 Relay Output Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe BMXDRA1605H provides 16 relay-based discrete output channels with positive output logic. The relay contacts support field circuits from 19 to 264 VAC and 19 to 30 VDC within the specified nominal ranges. The minimum switching current is 1 mA at 5 VDC. Output response is specified at less than 8 ms for activation and less than 10 ms for deactivation.\u003c\/p\u003e\n\u003cp\u003eThe module operates from the Modicon X80 common I\/O platform used with Modicon M580 and M340 Programmable Automation Controllers. Its conformal coating and stated environmental classifications support installation in severe environmental conditions. The module has an IP20 enclosure rating and requires appropriate cabinet-level protection against direct exposure to liquids and conductive contamination.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many discrete outputs are provided by the BMXDRA1605H?\u003c\/p\u003e\n\u003cp\u003eA: The module provides 16 normally open relay outputs with positive discrete output logic.\u003c\/p\u003e\n\u003cp\u003eQ: What field voltage ranges are supported by the relay outputs?\u003c\/p\u003e\n\u003cp\u003eA: The specified ranges are 19-30 VDC for DC circuits and 19-264 VAC for AC circuits, with nominal values of 24 VDC and 240 VAC.\u003c\/p\u003e\n\u003cp\u003eQ: What is the specified output response time?\u003c\/p\u003e\n\u003cp\u003eA: Output activation is specified at less than 8 ms, while output deactivation is specified at less than 10 ms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the BMXDRA1605H in the appropriate Modicon X80 rack and verify that the module position and terminal arrangement correspond to the system configuration.\u003c\/p\u003e\n\u003cp\u003eBefore wiring, isolate field power and verify the intended AC or DC circuit voltage. Select conductors and external protection according to the connected load and applicable electrical installation requirements.\u003c\/p\u003e\n\u003cp\u003eKeep relay output wiring separated from low-level analog, communication, and sensitive signal wiring where practical. Route high-current or inductive load conductors separately from signal circuits to reduce conducted and radiated interference.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shields according to the plant grounding design. Do not use the module enclosure or signal wiring as an uncontrolled protective-earth path.\u003c\/p\u003e\n\u003cp\u003eBecause the module is IP20 rated, install it inside an enclosure providing the required environmental and electrical protection. Verify temperature, humidity, contamination, and mechanical conditions against the specified installation environment before energizing the rack.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50125417906418,"sku":"BMXDRA1605H","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/BMXDRA1605H.jpg?v=1789894952","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-bmxdra1605h-modicon-x80-discrete-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}