{"product_id":"schneider-electric-bmxami0800ru-modicon-m340-m580-analog-input-module","title":"Schneider Electric BMXAMI0800RU Modicon M340\/M580 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXAMI0800RU\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBMXAMI0800RU\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for acquiring voltage and current field signals within Modicon M340 and Modicon M580 PAC backplane systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXAMI0800RU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C measurement accuracy range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 150 mA at 24 VDC backplane supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh-density Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eModicon M340 \/ Modicon M580 PAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eHigh-level voltage and current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e0...10 V, 0...5 V, 1...5 V, +\/-5 V, +\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Range\u003c\/td\u003e\n\u003ctd\u003e0...20 mA, 4...20 mA, +\/-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits ADC, 15 bits + sign analog input resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 MOhm in voltage mode, 250 Ohm in current mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003e28-pin removable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1400 V DC between channels and ground, 1400 V DC between channels and bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Filtering\u003c\/td\u003e\n\u003ctd\u003eFirst order digital filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrosstalk Attenuation\u003c\/td\u003e\n\u003ctd\u003eMinimum 80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e100 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon PAC Analog Signal Processing Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe BMXAMI0800RU performs analog signal conversion through 8 configurable input channels connected to Modicon M340 and Modicon M580 backplane architectures. The module accepts standard transmitter signals including 4-20 mA loops and voltage outputs, converting field measurements into digital values ranging from -32768 to +32767 in the user scaling format.\u003c\/p\u003e\n\u003cp\u003eThe module supports channel configuration for different voltage and current ranges. Input protection allows overload conditions up to +\/-30 mA for current inputs and +\/-30 V for voltage inputs. Factory calibration, digital filtering, and internal conversion resistor accuracy of 0.1% with 15 ppm\/deg C drift characteristics define the analog acquisition behavior.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the BMXAMI0800RU provide channel-to-channel electrical isolation?\u003cbr\u003eA: The available specifications indicate 1400 V DC isolation between channels and ground, and between channels and the bus. Some Schneider Electric documentation variants list channel isolation characteristics differently; installation should follow the applicable hardware reference manual.\u003c\/p\u003e\n\u003cp\u003eQ: What is the analog conversion cycle time of the module?\u003cbr\u003eA: The fast read cycle time is 1 ms plus 1 ms multiplied by the number of configured channels. The nominal read cycle time for 8 channels is 9 ms.\u003c\/p\u003e\n\u003cp\u003eQ: Which field signal types can be connected to the input channels?\u003cbr\u003eA: The module accepts voltage signals including 0...10 V, 0...5 V, 1...5 V, +\/-5 V, +\/-10 V and current signals including 0...20 mA, 4...20 mA, and +\/-20 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the BMXAMI0800RU directly into a compatible Modicon M340 or Modicon M580 rack position according to the controller hardware configuration manual.\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation wiring for analog field connections where signal noise may affect measurement accuracy. Connect cable shields according to the cabinet grounding design and avoid routing analog signal cables parallel to high-current power conductors.\u003c\/p\u003e\n\u003cp\u003eVerify terminal block wiring before energizing the rack. Configure each input channel according to the connected transmitter output range to prevent scaling errors. Maintain separation between analog signal wiring and switching circuits to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eConfirm backplane power availability and module addressing before downloading the PLC\/PAC configuration.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50112768999666,"sku":"BMXAMI0800RU","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/BMXAMI0800RU2.jpg?v=1789727032","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-bmxami0800ru-modicon-m340-m580-analog-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}