{"product_id":"schneider-electric-bmep584040s-modicon-m580-safety-processor-module","title":"Schneider Electric BMEP584040S Modicon M580 Safety Processor Module","description":"\u003cp\u003eConfigured for standalone safety processing in Modicon M580 PAC platforms, the \u003cstrong\u003eSchneider Electric BMEP584040S\u003c\/strong\u003e (\u003cstrong\u003eBMEP584040S\u003c\/strong\u003e Processor Module) provides direct physical and logical execution for safety control, process control, and Ethernet-based I\/O communication tasks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMEP584040S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon M580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Function\u003c\/td\u003e\n\u003ctd\u003eStandalone safety processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3 IEC 61508 \/ IEC 61511, SILCL 3 IEC 62061, SILCL 3 ISO 13849-1 category 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e4096 discrete channels, 1024 analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Specific Channels\u003c\/td\u003e\n\u003ctd\u003e144 local rack channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 16 remote I\/O stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistributed Equipment Capacity\u003c\/td\u003e\n\u003ctd\u003e64 devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIP Safety Device Capacity\u003c\/td\u003e\n\u003ctd\u003e64 devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interfaces\u003c\/td\u003e\n\u003ctd\u003e1 Ethernet TCP\/IP service port, 2 Ethernet TCP\/IP device network ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Interface\u003c\/td\u003e\n\u003ctd\u003eUSB type mini B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e16 MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory\u003c\/td\u003e\n\u003ctd\u003e2048 kB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Program Memory\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Data Memory\u003c\/td\u003e\n\u003ctd\u003e1024 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e10 kB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003eExpandable 4 GB flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eRIO scanner, DIO scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Modules Capacity\u003c\/td\u003e\n\u003ctd\u003e16 AS-Interface modules, 4 Ethernet communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Processing\u003c\/td\u003e\n\u003ctd\u003e30 Kinst\/ms (65% Boolean + 35% fixed arithmetic), 40 Kinst\/ms (100% Boolean)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e295 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.849 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003ePackage dimensions: 8.9 cm x 17.8 cm x 25.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Interface\u003c\/td\u003e\n\u003ctd\u003eModicon M580 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, ATEX Zone 2\/22, IECEx Zone 2\/22, TUV, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet PAC Safety Processing and Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe BMEP584040S integrates safety processing functions within the Modicon M580 Ethernet PAC architecture. The processor manages local X80 I\/O racks, Quantum I\/O compatibility, distributed Ethernet devices, and CIP Safety devices through deterministic network communication.\u003c\/p\u003e\n\u003cp\u003eThe module supports Ethernet TCP\/IP service communication, dual Ethernet device network connections, and embedded cybersecurity functions including IPSec, SNMP logging, Syslog protocol support, audit trail recording, embedded firewall, firmware signature verification, and port hardening.\u003c\/p\u003e\n\u003cp\u003eThe processor architecture supports triple communication separation between standard control execution, safety tasks, and network services. Safety applications can include periodic safe tasks, event tasks, fast tasks, cyclic tasks, and master control tasks.\u003c\/p\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Safety Execution Architecture\u003c\/h3\u003e\n\u003cp\u003eThe BMEP584040S uses integrated RAM and expandable flash storage for application programs, safety logic, and data retention. Firmware integrity functions include signed firmware validation and password protection mechanisms.\u003c\/p\u003e\n\u003cp\u003eSafety execution supports IEC 61508 based SIL 3 applications with dedicated safety memory areas. The processor provides status monitoring through dedicated LEDs for RUN, ERR, I\/O fault, download status, backup memory status, Ethernet network status, safety mode, maintenance mode, and forced I\/O indication.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the BMEP584040S support Modicon M580 redundant processor configurations?\u003cbr\u003eA: The BMEP584040S is a standalone safety processor module. Redundant processor configurations require compatible M580 redundancy hardware and system architecture.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are integrated on the processor module?\u003cbr\u003eA: The module includes one Ethernet TCP\/IP service port, two Ethernet TCP\/IP device network ports, and one USB type mini B programming interface.\u003c\/p\u003e\n\u003cp\u003eQ: What safety functions are supported by this processor?\u003cbr\u003eA: The processor supports IEC 61508 SIL 3 safety applications, safety control execution, safety tasks, and CIP Safety device communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the BMEP584040S in a compatible Modicon M580 rack with the rack power supply removed during insertion or removal procedures.\u003c\/p\u003e\n\u003cp\u003eConnect Ethernet network wiring according to industrial Ethernet installation practices. Maintain separation between power conductors and communication cables to reduce electromagnetic interference. Use shielded Ethernet cabling where required by the installation environment and connect cable shields according to cabinet grounding requirements.\u003c\/p\u003e\n\u003cp\u003eVerify rack addressing, I\/O configuration, firmware compatibility, and safety application parameters before commissioning. Confirm that safety logic validation procedures are completed before placing the processor into operational safety mode.\u003c\/p\u003e\n\u003cp\u003eThe conformal coated construction supports installation in environments with specified gas, dust, humidity, and industrial contamination classifications. Maintain enclosure protection according to the required IP rating of the overall control cabinet.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50112486703346,"sku":"BMEP584040S","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/BMEP584040S2.jpg?v=1789722952","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-bmep584040s-modicon-m580-safety-processor-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}