{"product_id":"schneider-electric-atv930d75n4-altivar-process-atv900-variable-speed-drive","title":"Schneider Electric ATV930D75N4 Altivar Process ATV900 Variable Speed Drive","description":"\u003cp\u003eConfigured for variable-frequency control of 3-phase synchronous and asynchronous motors in the Altivar Process ATV900 platform, the \u003cstrong\u003eSchneider Electric ATV930D75N4\u003c\/strong\u003e (\u003cstrong\u003eATV930D75N4\u003c\/strong\u003e Variable Speed Drive) accepts a 380 to 480 VAC supply and provides up to 145 A normal-duty output current. The unit includes an integrated braking chopper, IP21 enclosure, Ethernet communication, Modbus serial communication, and Safe Torque Off.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATV930D75N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Speed Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAltivar Process ATV900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariant\u003c\/td\u003e\n\u003ctd\u003eStandard version with braking chopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Type\u003c\/td\u003e\n\u003ctd\u003e3-phase synchronous and asynchronous motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 480 VAC, -15% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e145.0 A normal duty; 106.0 A heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power\u003c\/td\u003e\n\u003ctd\u003e75 kW normal duty; 55 kW heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Frequency\u003c\/td\u003e\n\u003ctd\u003e599 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e1 to 8 kHz adjustable; 2.5 to 8 kHz with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Switching Frequency\u003c\/td\u003e\n\u003ctd\u003e2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Chopper\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current\u003c\/td\u003e\n\u003ctd\u003e145 A normal duty; 106 A heavy duty at 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transient Current\u003c\/td\u003e\n\u003ctd\u003e174 A for 60 s normal duty; 159 A for 60 s heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, Modbus TCP, Modbus serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Serial Rate\u003c\/td\u003e\n\u003ctd\u003e4.8, 9.6, 19.2, 38.4 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, 2-wire RS 485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connector\u003c\/td\u003e\n\u003ctd\u003e2 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Connector\u003c\/td\u003e\n\u003ctd\u003e1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e3; 0 to 10 VDC or 0 to 20 mA \/ 4 to 20 mA, 12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2; 0 to 10 VDC or 0 to 20 mA, 10 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e10; DI1 to DI8 plus STOA and STOB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Inputs\u003c\/td\u003e\n\u003ctd\u003eDI7 and DI8, 0 to 30 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Torque Off\u003c\/td\u003e\n\u003ctd\u003eSTO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Stop 1\u003c\/td\u003e\n\u003ctd\u003eSS1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafely Limited Speed\u003c\/td\u003e\n\u003ctd\u003eSLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Brake Control\u003c\/td\u003e\n\u003ctd\u003eSBC\/SBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Filter\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP21; UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e290 mm W x 922 mm H x 325.5 mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e59 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-15 to 50 deg C without derating; 50 to 60 deg C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 m without derating; 1000 to 4800 m with 1% current derating per 100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e174 W natural convection at 380 V, 2.5 kHz; 1369 W forced convection at 380 V, 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Air Volume\u003c\/td\u003e\n\u003ctd\u003e295 m3\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Position\u003c\/td\u003e\n\u003ctd\u003eVertical +\/- 10 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Class\u003c\/td\u003e\n\u003ctd\u003e3C3 \/ 3S3 according to IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Communication\u003c\/h3\u003e\n\u003cp\u003eThe ATV930D75N4 provides Ethernet communication through EtherNet\/IP and Modbus TCP at 10\/100 Mbit\/s. The Ethernet interface supports half-duplex, full-duplex, and autonegotiation modes. Modbus serial communication uses a 2-wire RS 485 interface with RTU framing, configurable parity, and addresses from 1 to 247.\u003c\/p\u003e\n\u003cp\u003eThe drive also supports optional communication modules for PROFINET, Profibus DP V1, DeviceNet, EtherCAT, CANopen, and Ethernet Powerlink. These options are installed through the designated drive communication slots.\u003c\/p\u003e\n\u003cp\u003eThe control interface includes programmable 24 VDC discrete inputs, analog inputs, analog outputs, relay outputs, and pulse I\/O. Analog inputs accept voltage or current signals, while analog outputs can be configured for voltage or current operation.\u003c\/p\u003e\n\u003cp\u003eMotor control profiles include variable torque, optimized torque, and constant torque operation for asynchronous motors. Permanent magnet and synchronous reluctance motor profiles are also supported. Acceleration and deceleration ramps are separately adjustable from 0.01 to 9999 s.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What supply voltage is specified for the ATV930D75N4?\u003c\/p\u003e\n\u003cp\u003eA: The rated supply voltage is 380 to 480 VAC, with a specified supply tolerance of -15% to +10% and a network frequency range of 50 to 60 Hz.\u003c\/p\u003e\n\u003cp\u003eQ: Does the ATV930D75N4 include a braking chopper?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied configuration includes an integrated braking chopper.\u003c\/p\u003e\n\u003cp\u003eQ: Which safety functions are specified for this drive?\u003c\/p\u003e\n\u003cp\u003eA: The documented safety functions include Safe Torque Off (STO), Safe Stop 1 (SS1), Safely Limited Speed (SLS), and Safe Brake Control (SBC\/SBT).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the drive in the specified vertical position within the stated ambient temperature and altitude limits. Maintain the required clearance and airflow path around the enclosure so that the cooling system can operate without obstruction.\u003c\/p\u003e\n\u003cp\u003eUse the specified conductor sizes and terminal arrangements for control, DC bus, line-side, and motor connections. Separate power wiring from low-level analog and communication wiring where practical to reduce conducted and radiated interference.\u003c\/p\u003e\n\u003cp\u003eConnect protective earth according to the applicable installation standard. Route Ethernet and RS 485 communication cables separately from high-current motor conductors where possible. Use the designated communication connectors and maintain appropriate cable shielding and termination practices for the selected network.\u003c\/p\u003e\n\u003cp\u003eBefore energization, verify supply voltage, motor wiring, protective earth continuity, control polarity, STO wiring, and configured motor parameters. Confirm that the motor and drive ratings correspond to the selected normal-duty or heavy-duty operating mode.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50094419902706,"sku":"ATV930D75N4","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ATV930D75N42.jpg?v=1789549060","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-atv930d75n4-altivar-process-atv900-variable-speed-drive","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}