{"product_id":"schneider-electric-atv930c22n4-altivar-process-atv900-variable-speed-drive","title":"Schneider Electric ATV930C22N4 Altivar Process ATV900 Variable Speed Drive","description":"\u003cp\u003eConfigured for 3-phase motor speed control in the Altivar Process ATV900 platform, the \u003cstrong\u003eSchneider Electric ATV930C22N4\u003c\/strong\u003e (\u003cstrong\u003eATV930\u003c\/strong\u003e variable speed drive) provides direct electrical control for synchronous and asynchronous motors. The unit is rated for 380 to 480 VAC input, 220 kW normal-duty motor power, and includes an integrated braking chopper.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATV930C22N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eATV930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Speed Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAltivar Process ATV900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariant\u003c\/td\u003e\n\u003ctd\u003eStandard version with braking chopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Type\u003c\/td\u003e\n\u003ctd\u003eAsynchronous and synchronous motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 480 VAC, -15% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power\u003c\/td\u003e\n\u003ctd\u003e220 kW normal duty; 160 kW heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current\u003c\/td\u003e\n\u003ctd\u003e427 A normal duty; 302 A heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transient Current\u003c\/td\u003e\n\u003ctd\u003e512 A for 60 s normal duty; 453 A for 60 s heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Frequency\u003c\/td\u003e\n\u003ctd\u003e599 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e1 to 8 kHz adjustable; 2.5 to 8 kHz with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Switching Frequency\u003c\/td\u003e\n\u003ctd\u003e2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Chopper\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50 to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent Power\u003c\/td\u003e\n\u003ctd\u003e247 kVA at 480 V normal duty; 187 kVA at 480 V heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP, EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Serial Rate\u003c\/td\u003e\n\u003ctd\u003e4.8, 9.6, 19.2, 38.4 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, 2-wire RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connectors\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Connector\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e10; DI1 to DI8 programmable, DI7\/DI8 pulse input, STOA\/STOB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e3; 0 to 10 VDC or 0 to 20 mA \/ 4 to 20 mA, 12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2; 0 to 10 VDC or 0 to 20 mA, 10 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e3 configurable relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Torque Off\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Stop 1\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafely Limited Speed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Brake Management\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall mount, vertical +\/- 10 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e380 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e172 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 40 deg C without derating; 40 to 60 deg C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 m without derating; 1000 to 3000 m with current derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e5030 W forced convection at 380 V, 2.5 kHz; 451 W natural convection at 380 V, 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Air Volume\u003c\/td\u003e\n\u003ctd\u003e860 m3\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProspective Line Isc\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1 MOhm at 500 VDC for 1 minute to earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCSA, TÜV, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 61508, IEC 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Communication\u003c\/h3\u003e\n\u003cp\u003eThe ATV930C22N4 exchanges control and diagnostic data through Modbus serial, Modbus TCP, and EtherNet\/IP interfaces. Ethernet communication operates at 10\/100 Mbit\/s with half-duplex, full-duplex, and auto-negotiation modes. The serial Modbus interface uses RS-485 physical signaling with RTU framing and configurable odd, even, or no parity.\u003c\/p\u003e\n\u003cp\u003eThe drive provides 10 programmable discrete inputs, three analog inputs, two analog outputs, and three relay outputs. DI7 and DI8 can operate as pulse inputs up to 30 kHz. Analog inputs accept 0 to 10 VDC or 0 to 20 mA \/ 4 to 20 mA signals. Optional communication and I\/O modules support additional network and signal interfaces.\u003c\/p\u003e\n\u003cp\u003eMotor control profiles include constant torque, variable torque, and optimized torque modes for asynchronous motors, plus permanent magnet and synchronous reluctance motor control. The drive supports 4-quadrant operation, adjustable acceleration and deceleration ramps from 0.01 to 9999 s, and a maximum output frequency of 599 Hz.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ATV930C22N4 include a braking chopper?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The ATV930C22N4 has an integrated brake chopper for connection to the applicable braking circuit.\u003c\/p\u003e\n\u003cp\u003eQ: What motor feedback and control signals are available?\u003c\/p\u003e\n\u003cp\u003eA: The drive provides three analog inputs, two analog outputs, ten discrete inputs, two discrete outputs, and three configurable relay outputs. Encoder interface modules can be installed through the available option slots.\u003c\/p\u003e\n\u003cp\u003eQ: What safety functions are provided by this model?\u003c\/p\u003e\n\u003cp\u003eA: The documented safety functions include Safe Torque Off (STO), Safe Stop 1 (SS1), Safely Limited Speed (SLS), and Safe Brake Management (SBC\/SBT).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the drive vertically within the specified +\/- 10 deg position range. The enclosure is rated IP00, so installation requires an appropriate protective enclosure or cabinet providing the required environmental and personnel protection.\u003c\/p\u003e\n\u003cp\u003eRoute line-side power conductors, motor conductors, control wiring, and communication cables according to the installation manual. Keep low-level analog and communication wiring separated from high-current motor and input power conductors.\u003c\/p\u003e\n\u003cp\u003eConnect protective earth before energizing the power circuit. Maintain the specified conductor cross-sections and terminal arrangements for line, motor, DC bus, and control connections. Shielded signal and communication cables should be terminated according to the applicable EMC installation practice.\u003c\/p\u003e\n\u003cp\u003eProvide the required forced-convection cooling path. The specified cooling air volume is 860 m3\/h. Verify cabinet airflow, ambient temperature, altitude, and drive derating requirements before commissioning.\u003c\/p\u003e\n\u003cp\u003eFor EtherNet\/IP, Modbus TCP, and RS-485 connections, verify cable routing, connector seating, network addressing, and termination requirements before applying control commands. Do not route communication cables in parallel with high-current motor conductors unless the installation method provides the required EMC separation.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50089840279794,"sku":"ATV930C22N4","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ATV930C22N42.jpg?v=1789463654","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-atv930c22n4-altivar-process-atv900-variable-speed-drive","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}