{"product_id":"schneider-electric-atv630d45n4-altivar-process-atv600-variable-speed-drive","title":"Schneider Electric ATV630D45N4 Altivar Process ATV600 Variable Speed Drive","description":"\u003cp\u003eConfigured for three-phase motor speed control in the Altivar Process ATV600 platform, the \u003cstrong\u003eSchneider Electric ATV630D45N4\u003c\/strong\u003e (\u003cstrong\u003eATV630\u003c\/strong\u003e Variable Speed Drive) provides direct power conversion from a 380 to 480 VAC supply to synchronous or asynchronous motor loads. The drive provides 88 A continuous output at 4 kHz under normal duty, IP21 protection, integrated Modbus and Ethernet communications, and Safe Torque Off (STO) rated SIL 3.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATV630D45N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eATV630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eAltivar Process ATV600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Speed Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndia (IN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 480 VAC, 3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e50 to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power\u003c\/td\u003e\n\u003ctd\u003e45 kW normal duty; 37 kW heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Rating\u003c\/td\u003e\n\u003ctd\u003e60 hp normal duty; 50 hp heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd\u003e88 A normal duty; 74.5 A heavy duty at 4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0.1 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e2 to 12 kHz adjustable; 4 to 12 kHz with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Ethernet, Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet and 2-wire RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s Ethernet; 4800 to 38.4 Kbit\/s serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e3, software configurable, 0 to 10 VDC or 0 to 20 mA, 12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2, software configurable, 0 to 10 VDC or 0 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8; DI7 and DI8 support pulse input up to 30 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e3 configurable relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Function\u003c\/td\u003e\n\u003ctd\u003eSafe Torque Off (STO), SIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Filter\u003c\/td\u003e\n\u003ctd\u003eIntegrated; IEC 61800-3 Category C2\/C3 according to configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP21; UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eForced convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e226 x 673 x 271 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-15 to 50 deg C without derating; 50 to 60 deg C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower dissipation: 121 W natural convection or 943 W forced convection at 380 V, 4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall mounted, vertical +\/- 10 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e79.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transient Current\u003c\/td\u003e\n\u003ctd\u003e96.8 A for 60 s normal duty; 111.8 A for 60 s heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent Power\u003c\/td\u003e\n\u003ctd\u003e57.4 kVA at 480 V normal duty; 49.1 kVA at 480 V heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum THDI\u003c\/td\u003e\n\u003ctd\u003eLess than 48% from 80 to 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eMotor thermal protection, drive thermal protection, overcurrent, short circuit, overvoltage, undervoltage, phase loss, overspeed and STO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, ATEX Zone 2\/22, ATEX INERIS, CSA, TUV, DNV-GL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 61508, IEC 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe principal hardware and electrical values are taken from the supplied Schneider Electric product data.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Control and Drive Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe ATV630D45N4 uses Ethernet and 2-wire RS485 interfaces for control-system communication. Modbus TCP operates over Ethernet, while the serial interface supports RTU framing with configurable parity and addresses from 1 to 247. The communication interface supports 10\/100 Mbit\/s Ethernet and serial rates from 4800 bps to 38.4 Kbps.\u003c\/p\u003e\n\u003cp\u003eThe drive provides configurable analog and digital signal interfaces. AI1, AI2 and AI3 accept voltage or current signals, while AQ1 and AQ2 provide voltage or current outputs. DI7 and DI8 can operate as pulse inputs up to 30 kHz. Sampling durations are specified as 2 ms for DI1 to DI4, 5 ms for DI5 and DI6, 5 ms for analog inputs and 10 ms for AO1.\u003c\/p\u003e\n\u003cp\u003eMotor control profiles include constant torque, optimized torque and variable torque for asynchronous motors, plus permanent magnet and synchronous reluctance motor profiles. Acceleration and deceleration ramps are independently adjustable from 0.01 to 9999 s. The unit uses DC injection for braking to standstill and does not include an integrated brake chopper.\u003c\/p\u003e\n\u003cp\u003eOptional communication hardware includes PROFIBUS DP V1, PROFINET, DeviceNet, Modbus TCP\/EtherNet\/IP, CANopen, Ethernet\/IP Modbus TCP\/MD-Link, BACnet MS\/TP and Ethernet Powerlink modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interfaces are built into the ATV630D45N4?\u003cbr\u003eA: The drive has Ethernet and 2-wire RS485 physical interfaces, with Modbus serial and Modbus TCP communication supported as standard.\u003c\/p\u003e\n\u003cp\u003eQ: What is the continuous output current of the ATV630D45N4?\u003cbr\u003eA: Continuous output current is 88 A at 4 kHz for normal duty and 74.5 A at 4 kHz for heavy duty.\u003c\/p\u003e\n\u003cp\u003eQ: Does the ATV630D45N4 provide a safety function?\u003cbr\u003eA: Yes. Safe Torque Off (STO) is provided and specified as SIL 3.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the drive vertically on a wall within the specified +\/- 10 degree operating position. Maintain the required installation clearances specified by the applicable ATV630 installation documentation and ensure that forced-convection airflow is not obstructed.\u003c\/p\u003e\n\u003cp\u003eRoute incoming power, motor conductors and low-level control or communication wiring separately where practical to limit conducted and radiated interference. Use the specified control, line-side and motor terminal conductor ranges for the corresponding connections.\u003c\/p\u003e\n\u003cp\u003eConnect protective earth and cable shields according to the installation requirements for the drive and the connected motor system. Keep communication wiring away from high-current motor conductors and avoid unnecessary parallel runs.\u003c\/p\u003e\n\u003cp\u003eFor ambient temperatures from 50 to 60 deg C, apply the specified current derating. Above 1000 m altitude, apply the stated current derating of 1% per 100 m.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50089829957874,"sku":"ATV630D45N4","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ATV630D45N42.jpg?v=1789462935","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-atv630d45n4-altivar-process-atv600-variable-speed-drive","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}