{"product_id":"schneider-electric-atv630c31n4-altivar-process-atv600-variable-speed-drive","title":"Schneider Electric ATV630C31N4 Altivar Process ATV600 Variable Speed Drive","description":"\u003cp\u003eConfigured for three-phase motor speed regulation in the Altivar Process ATV600 platform, the \u003cstrong\u003eSchneider Electric ATV630C31N4\u003c\/strong\u003e (\u003cstrong\u003eATV630\u003c\/strong\u003e Variable Speed Drive) provides direct electrical control of synchronous and asynchronous motors from a 380 to 480 VAC supply. The unit supports up to 315 kW normal-duty motor power and 250 kW heavy-duty motor power, with Modbus serial and Ethernet\/Modbus TCP communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATV630C31N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eAltivar Process ATV600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd\u003eATV630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Speed Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 480 VAC, 3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e50 to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal-Duty Motor Power\u003c\/td\u003e\n\u003ctd\u003e315 kW \/ 500 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeavy-Duty Motor Power\u003c\/td\u003e\n\u003ctd\u003e250 kW \/ 400 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal-Duty Continuous Output Current\u003c\/td\u003e\n\u003ctd\u003e616 A at 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeavy-Duty Continuous Output Current\u003c\/td\u003e\n\u003ctd\u003e481 A at 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0.1 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e569 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, 2-wire RS485, Modbus TCP, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Rate\u003c\/td\u003e\n\u003ctd\u003e10 \/ 100 Mbit\/s Ethernet; 4800 to 38.4 Kbps serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e3, configurable 0 to 10 VDC or 0 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2, configurable 0 to 10 VDC or 0 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Function\u003c\/td\u003e\n\u003ctd\u003eSTO, SIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eForced convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall mounted, vertical +\/- 10 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e598 x 1195 x 380 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e203 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 40 deg C without derating; 40 to 60 deg C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e7099 W forced convection; 769 W natural convection at 380 V, 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP00; IP21 with VW3A9113 kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, TÜV, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61508, IEC 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatest Firmware Listed\u003c\/td\u003e\n\u003ctd\u003eV4.6IE47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe dimensional, electrical, environmental, certification, and origin data are taken from the supplied Schneider Electric product information.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Drive Control and Network Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe ATV630C31N4 provides Ethernet and 2-wire RS485 physical interfaces. Modbus TCP operates over Ethernet, while Modbus RTU is available through the serial interface with configurable transmission rates from 4800 bps to 38.4 Kbps. Ethernet supports 10 and 100 Mbit\/s operation with half-duplex, full-duplex, and autonegotiation modes.\u003c\/p\u003e\n\u003cp\u003eThe drive accepts configurable analog voltage and current signals through three analog inputs and provides two configurable analog outputs. Digital inputs include DI7 and DI8 pulse-input capability up to 30 kHz at 24 VDC. Optional communication modules include PROFINET, EtherNet\/IP, DeviceNet, Profibus DP V1, CANopen, BACnet MS\/TP, and other listed interfaces.\u003c\/p\u003e\n\u003cp\u003eMotor control profiles include constant torque, optimized torque, and variable torque modes for asynchronous motors, plus permanent-magnet and synchronous-reluctance motor control profiles. The switching frequency is adjustable within the specified 2 to 8 kHz range, subject to the applicable derating conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What motor types can the ATV630C31N4 control?\u003cbr\u003eA: The drive supports both asynchronous and synchronous motors, including permanent-magnet and synchronous-reluctance motor control profiles.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are integrated?\u003cbr\u003eA: The drive has Ethernet and 2-wire RS485 interfaces. Modbus TCP is available through Ethernet, and Modbus RTU is available through the serial interface.\u003c\/p\u003e\n\u003cp\u003eQ: Does the ATV630C31N4 provide a safety torque-off function?\u003cbr\u003eA: Yes. Safe Torque Off (STO) is listed as an integrated safety function with SIL 3 classification.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the drive vertically within the specified +\/- 10 deg operating position. Provide sufficient clearance for the forced-convection cooling path and maintain the specified ambient temperature limits. At temperatures above 40 deg C, apply the documented current derating.\u003c\/p\u003e\n\u003cp\u003eUse the specified removable screw terminals for control wiring and the specified line-side and motor-side terminals for power connections. Keep control and communication wiring separated from high-current motor conductors where practical to reduce conducted electrical interference. Connect cable shields and protective earth according to the applicable installation standard and the drive installation documentation.\u003c\/p\u003e\n\u003cp\u003eVerify supply voltage, motor connection, protective devices, STO wiring, communication addressing, and configured I\/O before energization. The product data specifies isolation between power and control terminals and provides dedicated protection functions for motor phase loss, overcurrent, short circuit, DC bus overvoltage, undervoltage, overheating, and related drive conditions.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50089827860722,"sku":"ATV630C31N4","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ATV630C31N42.jpg?v=1789462630","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-atv630c31n4-altivar-process-atv600-variable-speed-drive","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}