{"product_id":"schneider-electric-abl8rps24100-universal-power-supply","title":"Schneider Electric ABL8RPS24100 Universal Power Supply","description":"\u003cp\u003eConfigured for regulated 24 VDC auxiliary power generation in industrial automation control circuits, the \u003cstrong\u003eSchneider Electric ABL8RPS24100\u003c\/strong\u003e (\u003cstrong\u003eABL8RPS24100\u003c\/strong\u003e Power Supply) provides direct AC-to-DC conversion with adjustable output voltage, overload protection, and DIN-rail mounting.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eABL8RPS24100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon Power Supply \/ Phaseo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRegulated switch mode power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003ePhilippines (PH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC single phase; 200-500 VAC phase to phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC adjustable to 24-28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemporary Current Boost\u003c\/td\u003e\n\u003ctd\u003e150% of nominal current for 4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e87%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.68 at 240 VAC; 0.69 at 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e31 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Harmonic Control\u003c\/td\u003e\n\u003ctd\u003eLow-frequency harmonic current filter; IEC 61000-3-2 PFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eOverload, overvoltage, short-circuit, undervoltage, thermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e30-32 VDC, manual reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUndervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eTrip below 21.6 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e3500 V input-ground; 4000 V input-output; 500 V output-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 x 7.5 mm or 35 x 15 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Position\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e145 mm D x 125 mm H x 86 mm W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 50 deg C without derating; 50 to 60 deg C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eFront LED diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eScrew terminals and removable screw terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Standards\u003c\/td\u003e\n\u003ctd\u003eUL 508; CSA C22.2 No 60950-1; EN\/IEC 62368-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCCSAus, EAC, KC, RCM, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePower Conditioning and Industrial Control Interface\u003c\/h3\u003e\n\u003cp\u003eThe ABL8RPS24100 incorporates a power factor correction filter for input current harmonic control and provides an adjustable 24-28.8 VDC output. The output can be connected in parallel or series configurations. Front-mounted LED indicators provide output voltage and output current status.\u003c\/p\u003e\n\u003cp\u003eThe protection circuitry monitors overload, short-circuit, overvoltage, undervoltage, and thermal conditions. Automatic reset is provided for specified short-duration fault conditions, while the overvoltage protection is specified for 30-32 VDC with manual reset.\u003c\/p\u003e\n\u003cp\u003eThe unit uses DIN-rail mounting and a vertical operating position. Input, output, and grounding connections use screw-type terminals with conductor ranges specified by the manufacturer. The electrical separation is rated at 4000 V between input and output.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What output voltage range can be adjusted on the ABL8RPS24100?\u003c\/p\u003e\n\u003cp\u003eA: The output is rated at 24 VDC and can be adjusted from 24 to 28.8 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What temporary overload capability is specified?\u003c\/p\u003e\n\u003cp\u003eA: The power supply can deliver 150% of its nominal output current for 4 s.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting arrangement is specified?\u003c\/p\u003e\n\u003cp\u003eA: The unit mounts vertically on a 35 x 7.5 mm or 35 x 15 mm symmetrical DIN rail.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the power supply vertically on the specified symmetrical DIN rail and maintain the manufacturer's required ventilation clearance around the enclosure. Verify the AC input configuration before energization because the input terminals support different single-phase and phase-to-phase voltage ranges.\u003c\/p\u003e\n\u003cp\u003eConnect protective grounding through the designated ground terminal. Separate AC input wiring from low-voltage DC control wiring where practical to reduce conducted and radiated interference. Use the specified terminal conductor sizes and secure all screw terminals to the manufacturer's installation requirements.\u003c\/p\u003e\n\u003cp\u003eBefore connecting downstream automation loads, verify the adjusted DC output voltage. When the output is used for sensitive PLC, I\/O, or instrumentation circuits, check the total load current against the 10 A rated output and account for the specified temperature derating above 50 deg C.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50053371625714,"sku":"ABL8RPS24100","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ABL8RPS241002.jpg?v=1789024179","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-abl8rps24100-universal-power-supply","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}