{"product_id":"schneider-electric-140cpu65260c-modicon-quantum-cpu-module","title":"Schneider Electric 140CPU65260C Modicon Quantum CPU Module","description":"\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003eConfigured for programmable logic execution and Ethernet communication management in Modicon Quantum automation platforms, the \u003cstrong\u003eSchneider Electric 140CPU65260C\u003c\/strong\u003e (\u003cstrong\u003e140CPU65260C\u003c\/strong\u003e CPU Module) provides direct processor control, memory handling, and network interface functions. This Unity Programmable Automation Controller CPU module integrates a 266 MHz processor, internal RAM, Modbus communication interfaces, and Quantum backplane connectivity.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140CPU65260C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.15 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2500 mA at 5.1 VDC via Quantum backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum Automation Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eUnity Programmable Automation Controller CPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eIntel Pentium processor, 266 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory Capacity\u003c\/td\u003e\n\u003ctd\u003e3072 KB internal RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory\u003c\/td\u003e\n\u003ctd\u003e7168 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Execution Time\u003c\/td\u003e\n\u003ctd\u003e0.045 us Boolean, 0.045-0.09 us Words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Ethernet Port\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45 Ethernet, 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication Ports\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232\/485 Modbus\/ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Plus Port\u003c\/td\u003e\n\u003ctd\u003e1 x DB9 Modbus Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal\/Remote Rack Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 64 local or remote racks depending on network configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003eQuantum backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Support\u003c\/td\u003e\n\u003ctd\u003eExternal lithium battery 140XCP50000 for RAM retention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating, C-suffix configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon Quantum PAC Processing and Network Functions\u003c\/h3\u003e\n\u003cp\u003eThe 140CPU65260C CPU module provides PLC execution, memory management, and communication processing within the Modicon Quantum architecture. The integrated Ethernet interface supports 10\/100 Mbps network communication, while Modbus and Modbus Plus ports provide compatibility with existing industrial communication structures.\u003c\/p\u003e\n\u003cp\u003eThe Unity processor architecture supports firmware-based application execution and memory retention through the external lithium battery system. The conformal coating option improves protection against environmental contamination during industrial operation.\u003c\/p\u003e\n\u003cp\u003eThe module supports Quantum backplane bus communication with defined current consumption requirements. System expansion is configured through local and remote rack arrangements according to the installed I\/O network design.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 140CPU65260C support hot-swapping during system operation?\u003cbr\u003eA: The CPU module hot-swap capability depends on the Quantum system architecture and configured redundancy functions. Installation and removal procedures must follow Schneider Electric Quantum platform guidelines.\u003c\/p\u003e\n\u003cp\u003eQ: What power source does the 140CPU65260C require?\u003cbr\u003eA: The module receives operating power through the Quantum backplane bus and consumes 2500 mA at 5.1 VDC according to the provided technical specifications.\u003c\/p\u003e\n\u003cp\u003eQ: How is RAM data retention maintained after power interruption?\u003cbr\u003eA: RAM retention is supported by an external lithium battery module identified as 140XCP50000.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 140CPU65260C module directly into the designated Modicon Quantum rack slot with correct backplane alignment. Verify that the rack power supply is disconnected before module insertion or removal.\u003c\/p\u003e\n\u003cp\u003eConnect Ethernet, Modbus, and Modbus Plus communication cables according to network wiring specifications. Keep communication cables separated from high-voltage power conductors to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shields according to plant grounding standards. Avoid creating multiple grounding paths that may introduce circulating currents. Confirm battery installation status before commissioning to maintain RAM retention functions.\u003c\/p\u003e\n\u003cp\u003eVerify firmware compatibility between the CPU module, Unity programming environment, and installed Quantum hardware configuration before application download.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50010480935154,"sku":"140CPU65260C","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/140CPU65260C2.jpg?v=1788251104","url":"https:\/\/www.petrospare.com\/products\/schneider-electric-140cpu65260c-modicon-quantum-cpu-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}