{"product_id":"plx32-mbtcp-pnd-prosoft-modbus-tcp-ip-to-profinet-device-gateway","title":"PLX32-MBTCP-PND ProSoft Modbus TCP\/IP to PROFINET Device Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePLX32-MBTCP-PND\u003c\/strong\u003e is a ProSoft Modbus TCP\/IP to PROFINET Device Gateway providing data exchange between Modbus TCP\/IP and PROFINET networks.\u003c\/p\u003e\n\n\u003ch3\u003eModbus TCP\/IP Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupported Modbus Function Codes:\u003c\/strong\u003e 1, 2, 3, 4, 5, 6, 15, 16, 22 (Slave Only), 23 (Slave Only)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupported Clients:\u003c\/strong\u003e 10\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupported Servers (MBAP):\u003c\/strong\u003e 5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEncapsulated Servers:\u003c\/strong\u003e 5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommand List:\u003c\/strong\u003e Up to 160 fully configurable Client commands\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus Data:\u003c\/strong\u003e Error codes reported individually for each command\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommand List Polling:\u003c\/strong\u003e Each command individually enabled\/disabled; write‑only‑on‑data‑change available\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePROFINET Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDriver Type:\u003c\/strong\u003e Class A Device\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePROFINET I\/O Data:\u003c\/strong\u003e 1440 bytes IN, 1440 bytes OUT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExchange Types:\u003c\/strong\u003e Cyclic Real‑time (RT) and Acyclic Data\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePower Supply\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAllowed Range:\u003c\/strong\u003e 10 to 36V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e Positive, Negative, GND\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Load:\u003c\/strong\u003e 24V DC nominal @ 300 mA; 10‑36V DC @ 610 mA max\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTemperature \u0026amp; Humidity\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e –25°C to +70°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e –40°C to +80°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% RH (non‑condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShock \u0026amp; Vibration\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock (Operational):\u003c\/strong\u003e IEC 60068‑2‑27; 15G @ 11ms, 3‑Axis\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock (Non‑Operational):\u003c\/strong\u003e IEC 60068‑2‑27; 30G @ 18ms, 3‑Axis\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e IEC 60068‑2‑6; 5G @ 10Hz to 150Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eH × W × D:\u003c\/strong\u003e 5.38 × 1.99 × 4.38 in (13.67 × 5.05 × 11.13 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLED Indicators\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfiguration (CFG) and Error (ERR) Status\u003c\/li\u003e\n  \u003cli\u003ePower (PWR) and Hardware Fault (FLT)\u003c\/li\u003e\n  \u003cli\u003eNetwork Status (NS) – Modbus TCP Class I or Class III Connection Status\u003c\/li\u003e\n  \u003cli\u003eModule Status (MS) – Module Configuration Status\u003c\/li\u003e\n  \u003cli\u003eEthernet Communication Port Link\/Activity and 100 Mbit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEthernet Ports\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 2 × 10\/100 Mbit full‑ and half‑duplex RJ45\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e 1500 Vrms at 50‑60 Hz for 60 seconds per IEC 60950\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroadcast Storm Resiliency:\u003c\/strong\u003e ≤ 5000 ARP frames‑per‑second and ≤ 5 minutes duration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncluded Accessories\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2.5 mm screwdriver\u003c\/li\u003e\n  \u003cli\u003eJ180 Power Connector\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":49941330297074,"sku":"PLX32-MBTCP-PND","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/PLX32-MBTCP-PND.jpg?v=1787034652","url":"https:\/\/www.petrospare.com\/products\/plx32-mbtcp-pnd-prosoft-modbus-tcp-ip-to-profinet-device-gateway","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}