{"product_id":"honeywell-fs-tro-1024-digital-output-relay-contact-field-termination-assembly","title":"Honeywell FS-TRO-1024 Digital Output Relay Contact Field Termination Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-TRO-1024\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFS-TRO-1024\u003c\/strong\u003e digital output relay contact field termination assembly (FTA), provides the electrical interface between the SIC-C-12 system interconnection cable and external field wiring. It connects ten output channels from a 10208\/2\/1 digital output module or redundant module pair to field circuits through screw terminals. The assembly supports standard DIN EN rail mounting and provides relay contact circuit termination.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-TRO-1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Relay Contact Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e60 x 70 x 54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e36 VAC \/ 50 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switched Power\u003c\/td\u003e\n\u003ctd\u003e100 W \/ 1000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Current\u003c\/td\u003e\n\u003ctd\u003e2 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eSIC-C-12 system interconnection cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Output Module\u003c\/td\u003e\n\u003ctd\u003e10208\/2\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Termination\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wire Cross-Section\u003c\/td\u003e\n\u003ctd\u003e2.5 mm2 (AWG 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Stripping Length\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Tightening Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIN Rail Compatibility\u003c\/td\u003e\n\u003ctd\u003eTS32 \/ TS35 x 7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Rail Length\u003c\/td\u003e\n\u003ctd\u003e61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCategory III, according to the supplied IEC 1010 (1990) reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE; UL approval pending in the supplied documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRelay Output Interface and Electrical Limits\u003c\/h3\u003e\n\u003cp\u003eThe FS-TRO-1024 routes ten digital output channels from the 10208\/2\/1 module through the SIC-C-12 interconnection cable to field wiring terminals. The connected output module provides the relay contacts; the FTA serves as the field wiring termination interface.\u003c\/p\u003e\n\u003cp\u003eEach channel supports a maximum continuous current of 2 A. The documented maximum switching limits are 36 VAC or 50 VDC and 100 W \/ 1000 VA. These ratings must be considered together with the connected load characteristics and the output module's contact specifications.\u003c\/p\u003e\n\u003cp\u003eThe documentation identifies gold-flush silver-cadmium oxide as the contact material on the 10208\/2\/1 module. This material specification refers to the output module contacts, not the FS-TRO-1024 terminal assembly itself.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the FS-TRO-1024 support a redundant pair of 10208\/2\/1 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied documentation states that the ten channels of a redundant pair of 10208\/2\/1 modules can be connected to the FTA through the SIC-C-12 cable. The actual redundancy arrangement and switching behavior depend on the system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the electrical limits of the field wiring connections?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The documented maximum voltage is 36 VAC or 50 VDC, with a maximum switched power of 100 W \/ 1000 VA and a maximum continuous current of 2 A per channel. The connected load must remain within the applicable voltage, current, and switching limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which wire sizes and DIN rails are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The screw terminals accept conductors up to 2.5 mm2 (AWG 14), with a specified stripping length of 7 mm and tightening torque of 0.5 Nm. Mounting is supported on TS32 and TS35 x 7.5 DIN EN rails, requiring 61 mm of rail length.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN rail mounting:\u003c\/strong\u003e Install the FTA on a compatible TS32 or TS35 x 7.5 rail. Allow sufficient clearance for terminal access and cable routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem cable connection:\u003c\/strong\u003e Connect the SIC-C-12 cable according to the applicable system wiring diagram and the manufacturer's SIC-to-FTA application documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField wiring:\u003c\/strong\u003e Use conductors with a cross-section no greater than 2.5 mm2. Strip 7 mm of insulation and tighten terminal screws to 0.5 Nm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical load verification:\u003c\/strong\u003e Confirm that field circuit voltage, continuous current, and switching power remain within the documented limits. Check AC and DC load characteristics before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and shielding:\u003c\/strong\u003e Follow the system grounding design and cable shielding requirements. Do not assume that the FTA provides galvanic isolation or a dedicated shield termination without confirmation from the connection documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Verify terminal assignments, cable continuity, output channel mapping, and field load operation before placing the connected system into service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67785126543602,"sku":"FS-TRO-1024","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/FS-TRO-10242.jpg?v=1792376944","url":"https:\/\/www.petrospare.com\/products\/honeywell-fs-tro-1024-digital-output-relay-contact-field-termination-assembly","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}