{"product_id":"ge-ic698psd300-rx7i-pacsystems-dc-power-supply","title":"GE IC698PSD300 Rx7i PACSystems DC Power Supply","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc Emerson IC698PSD300\u003c\/strong\u003e is a DC power supply designed for the Rx7i PACSystems platform. It accepts a nominal 24 VDC input, with an operating input range of 18 to 30 VDC, and provides up to 300 W of total output power. Its output rails, integral electrical and thermal protection, and status indicators support power distribution and condition monitoring within the PACSystems hardware configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC698PSD300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eRx7i PACSystems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Power\u003c\/td\u003e\n\u003ctd\u003e300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Power\u003c\/td\u003e\n\u003ctd\u003e550 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 VDC Output Rail\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 VDC Output Rail\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Start Inrush Current\u003c\/td\u003e\n\u003ctd\u003e100 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide-Through Time\u003c\/td\u003e\n\u003ctd\u003e15 ms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Test Rating\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Protection\u003c\/td\u003e\n\u003ctd\u003eOvervoltage, overcurrent, overtemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eOutput OK (green LED), Fault (red LED)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.83 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Rail Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC698PSD300 supplies three regulated DC output rails to the RX7i backplane:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e+5 VDC:\u003c\/strong\u003e Up to 50 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+12 VDC:\u003c\/strong\u003e Up to 10 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-12 VDC:\u003c\/strong\u003e Up to 4 A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe three rails share a combined maximum output capacity of 300 W. When configuring a rack, calculate the load on each rail separately and verify that the combined power demand remains within the power supply rating. The individual current limits do not mean that all three rails can deliver their maximum output simultaneously.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Characteristics and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 18-30 VDC input range allows the module to operate from a nominal 24 VDC supply. Its cold-start inrush current can reach 100 A, so the upstream DC source and input protection must accommodate the startup demand. The specified minimum 15 ms ride-through time provides short-term tolerance to input interruptions.\u003c\/p\u003e\n\u003cp\u003eThe power supply also incorporates overvoltage, overcurrent, and overtemperature protection. Its input and output circuits are rated for 1500 VAC isolation testing over one minute.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCooling and Rack Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC698PSD300 is designed for installation in the power supply position of an RX7i rack (Slot 0). Forced-air cooling is required for operation at its full rated output capacity. The RX7i fan tray, mounted beneath the rack, supplies the cooling airflow.\u003c\/p\u003e\n\u003cp\u003eThe airflow monitoring and overtemperature protection functions are relevant during maintenance. Fan failure or restricted airflow can cause thermal protection to shut down the output rails, even when the electrical load is within the rated capacity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe front-panel status indicators help maintenance personnel identify the power supply operating condition:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput OK (green):\u003c\/strong\u003e Indicates that the DC output rails are operating within their specified ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver Temperature (red):\u003c\/strong\u003e Indicates an overtemperature condition or an airflow-related fault, according to the product documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input voltage is required for the IC698PSD300?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It requires a nominal 24 VDC input and supports an operating range of 18 to 30 VDC. The external supply must also accommodate the maximum 100 A cold-start inrush current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output voltages does the IC698PSD300 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides +5 VDC at up to 50 A, +12 VDC at up to 10 A, and -12 VDC at up to 4 A. The combined output power must remain within the 300 W maximum rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC698PSD300 require a cooling fan?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Forced-air cooling is required for full-rated-power operation. The RX7i rack fan tray provides the necessary airflow, and the airflow path should be checked during maintenance.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":69504479920370,"sku":"IC698PSD300","price":352.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/IC698PSD300.jpg?v=1795672074","url":"https:\/\/www.petrospare.com\/products\/ge-ic698psd300-rx7i-pacsystems-dc-power-supply","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}