{"product_id":"ge-ic200mdl940f-versamax-16-point-isolated-relay-output-module","title":"GE IC200MDL940F VersaMax 16-Point Isolated Relay Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200MDL940F\u003c\/strong\u003e is a 16-point relay output module in the VersaMax I\/O product family. It provides individually isolated Form A (normally open) relay contacts for switching external AC and DC loads. Each output operates as an independent dry contact, allowing the PLC to control field devices using separately supplied load power rather than sourcing the load voltage directly from the module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL940F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eIC200MDL940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact Type\u003c\/td\u003e\n\u003ctd\u003eForm A, Normally Open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Mechanism\u003c\/td\u003e\n\u003ctd\u003eFixed coil, moving armature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eSilver alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (DC)\u003c\/td\u003e\n\u003ctd\u003e0-125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range (AC)\u003c\/td\u003e\n\u003ctd\u003e0-265 VAC, 47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e5\/24\/125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A per point, 5-265 VAC resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Load Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A per point, 5-30 VDC resistive; 0.2 A per point, 31-125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e10 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.3 V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Response Time\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Response Time\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e20 cycles per minute (inductive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup-to-Group Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint-to-Point Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput-to-Logic Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 V Backplane Current Consumption\u003c\/td\u003e\n\u003ctd\u003e490 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eRelay Output Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL940F uses electromechanical relays with normally open Form A contacts. When the PLC commands an output ON, the corresponding relay energizes and closes its contact, completing the external load circuit. When the command is removed, the contact opens.\u003c\/p\u003e\n\u003cp\u003eBecause the outputs are individually isolated, each channel can switch its own externally supplied AC or DC circuit. This arrangement separates the PLC backplane logic from the field load supply and allows different output channels to operate independent circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLoad Ratings and Switching Limitations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe output current rating depends on the applied voltage and load type. For resistive loads, the contacts support up to 2.0 A per point at 5-265 VAC or 5-30 VDC. For DC loads between 31 and 125 VDC, the maximum current is reduced to 0.2 A per point.\u003c\/p\u003e\n\u003cp\u003eThe specified inductive-load switching frequency is 20 cycles per minute. The module has no internal fuses or snubbers, so external circuit protection and appropriate suppression for inductive loads must be considered when designing the field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Indication and Backplane Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach output point has an individual green LED indicating its ON\/OFF state. An additional OK LED indicates the presence of backplane power. The module draws up to 490 mA from the 5 V backplane supply, which should be included when calculating the power budget of the VersaMax I\/O assembly.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many independently isolated outputs does the IC200MDL940F provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides 16 individually isolated Form A normally open relay outputs. Each point can switch an independently supplied AC or DC load within its specified electrical ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IC200MDL940F switch both AC and DC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It supports 0-265 VAC and 0-125 VDC. However, the allowable current depends on the voltage range: DC loads above 30 VDC are limited to 0.2 A per point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC200MDL940F include internal output fuses or snubbers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The module has no internal fuses or snubbers. External protection and suitable inductive-load suppression should therefore be evaluated as part of the field circuit design.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":69482681204978,"sku":"IC200MDL940F","price":352.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/IC200MDL940F.jpg?v=1795589642","url":"https:\/\/www.petrospare.com\/products\/ge-ic200mdl940f-versamax-16-point-isolated-relay-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}