{"title":"Overspeed Detection","description":"\u003cp\u003eEnsure safety and equipment protection with advanced overspeed detection systems. Prevent catastrophic failures in turbines, engines, motors, and other rotating machinery by monitoring speed and triggering automatic shutdowns.\u003c\/p\u003e","products":[{"product_id":"ge-fanuc-ds200tceag1btf-emergency-overspeed-board","title":"GE Fanuc DS200TCEAG1BTF | Emergency Overspeed Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: \u003cstrong\u003eDS200TCEAG1BTF\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: Mark V Turbine Control System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDescription\u003c\/strong\u003e: Emergency overspeed board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e: Integrated into the board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPROM Sockets\u003c\/strong\u003e: Multiple sockets for programmability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuses\u003c\/strong\u003e: 3 fuses for voltage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumpers\u003c\/strong\u003e: 30 jumpers for customization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors\u003c\/strong\u003e: 2 bayonet connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctionality\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Function\u003c\/strong\u003e: Emergency overspeed control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnological Base\u003c\/strong\u003e: Incorporates Speedtronic technology\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47174660587762,"sku":"DS200TCEAG1BTF","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/DS200TCEAG1BTF_1_8c5ec15b-09f2-4a8e-b10f-dd26e0e43e61.jpg?v=1740561031"},{"product_id":"3300-53-03-02-00-60-20-00-00-00-bently-nevada-overspeed-protection-system","title":"3300\/53-03-02-00-60-20-00-00-00 Bently Nevada Overspeed Protection System","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct No.\u003c\/strong\u003e: \u003cstrong\u003e3300\/53-03-02-00-60-20-00-00-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Overspeed Protection System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLEDs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGreen\u003c\/strong\u003e: Annunciates the CHANNEL OK condition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRed\u003c\/strong\u003e: Annunciates OVERSPEED and TEST MODE conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder\u003c\/strong\u003e: Output proportional to selected full-scale RPM range.\n\u003cul\u003e\n\u003cli\u003eProtected against continuous short circuit to ground.\u003c\/li\u003e\n\u003cli\u003eOutput range: +4 mA to +20 mA, +12 Vdc compliance; +1 Vdc to +5 Vdc, 100 Ω minimum output impedance; 0 Vdc to -10 Vdc, 100 Ω minimum output impedance.\u003c\/li\u003e\n\u003cli\u003eNote: The recorder output is for data logging purposes only and is not suitable for use as a control system input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Power\u003c\/strong\u003e: -24 Vdc Power Supply, short-circuit protected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarms and OK\u003c\/strong\u003e: Relay drives for OVERSPEED and CHANNEL OK.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: +32°F to +149°F (0°C to +65°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°F to +185°F (-40°C to +85°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 0 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47269214585074,"sku":"3300\/53-03-02-00-60-20-00-00-00","price":275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/330053-03-02-00-60-20-00-00-00_2.jpg?v=1740560700"},{"product_id":"bently-nevada-133396-01-overspeed-detection-i-o-module-3500-53","title":"Bently Nevada - 133396-01 Overspeed Detection I\/O Module 3500\/53","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e133396-01\u003c\/strong\u003e is an Overspeed Detection I\/O Module designed for the Bently Nevada 3500\/53 system.\u003c\/p\u003e\n\u003ch3\u003ePhysical Dimensions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 241.3 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 24.4 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 99.1 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.45 kg (1.0 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Space:\u003c\/strong\u003e 1 full-height rear slot per channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30 °C to +65 °C (-22 °F to +149 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 °C to +85 °C (-40 °F to +185 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47290277593330,"sku":"133396-01","price":266.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/133396-01_2.jpg?v=1740560613"},{"product_id":"133388-01-bently-nevada-3500-53-overspeed-detection-module","title":"133388-01 - Bently Nevada - 3500\/53 Overspeed Detection Module","description":"\u003ch3 data-end=\"14\" data-start=\"0\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-end=\"171\" data-start=\"15\"\u003e\u003cstrong data-end=\"28\" data-start=\"15\"\u003e133388-01\u003c\/strong\u003e is an Overspeed Detection Module for the Bently Nevada 3500\/53 system, designed for precise speed monitoring and alarm setpoint adjustments.\u003c\/p\u003e\n\u003ch3 data-end=\"193\" data-start=\"173\"\u003eAlarm Settings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong data-end=\"216\" data-start=\"196\"\u003eAlarm Setpoints:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul data-end=\"364\" data-start=\"221\"\u003e\n\u003cli data-end=\"262\" data-start=\"221\"\u003eUnder and Over Alert levels for speed\u003c\/li\u003e\n\u003cli data-end=\"306\" data-start=\"265\"\u003eDanger (Overspeed) setpoint for speed\u003c\/li\u003e\n\u003cli data-end=\"364\" data-start=\"309\"\u003eAdjustable from 0 to 100% of full-scale speed range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"426\" data-start=\"365\"\u003e\n\u003cstrong data-end=\"389\" data-start=\"367\"\u003eAlarm Time Delays:\u003c\/strong\u003e\n\u003cul data-end=\"426\" data-start=\"394\"\u003e\n\u003cli data-end=\"426\" data-start=\"394\"\u003eLess than 30 ms above 300 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"453\" data-start=\"428\"\u003ePhysical Dimensions\u003c\/h3\u003e\n\u003cul data-end=\"558\" data-start=\"454\"\u003e\n\u003cli data-end=\"478\" data-start=\"454\"\u003e\n\u003cstrong data-end=\"467\" data-start=\"456\"\u003eHeight:\u003c\/strong\u003e 241.3 mm\u003c\/li\u003e\n\u003cli data-end=\"501\" data-start=\"479\"\u003e\n\u003cstrong data-end=\"491\" data-start=\"481\"\u003eWidth:\u003c\/strong\u003e 24.4 mm\u003c\/li\u003e\n\u003cli data-end=\"525\" data-start=\"502\"\u003e\n\u003cstrong data-end=\"514\" data-start=\"504\"\u003eDepth:\u003c\/strong\u003e 241.8 mm\u003c\/li\u003e\n\u003cli data-end=\"558\" data-start=\"526\"\u003e\n\u003cstrong data-end=\"539\" data-start=\"528\"\u003eWeight:\u003c\/strong\u003e 0.82 kg (1.8 lb)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47290397556978,"sku":"133388-01","price":222.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/133388-01.jpg?v=1740560610"},{"product_id":"286566-01-overspeed-detection-module-bently-nevada-3500-54m","title":"286566-01 Overspeed Detection Module Bently Nevada 3500\/54M","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e286566-01\u003c\/strong\u003e is a Bently Nevada Overspeed Detection Module (3500\/54M) designed to monitor and protect machinery from overspeed conditions, known for its reliability and fast response time.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Range:\u003c\/strong\u003e Voltage Range: +10.0 V to -24.0 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Compatibility:\u003c\/strong\u003e Proximity Probe Transducers, Magnetic Pickups\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Setpoints:\u003c\/strong\u003e User-defined for\n\u003cul\u003e\n\u003cli\u003eSpeed Monitoring\u003c\/li\u003e\n\u003cli\u003eRotor Acceleration\u003c\/li\u003e\n\u003cli\u003eReverse Rotation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47306095329522,"sku":"286566-01","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/350054M_286566-01__1.jpg?v=1740560536"},{"product_id":"protech-203-9907-147-woodward-overspeed-protection-systems","title":"ProTech 203 | 9907-147 | Woodward Overspeed Protection Systems","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e9907-147\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Woodward ProTech 203 Overspeed Protection System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem\u003c\/strong\u003e: De-Energize-to-Trip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 24 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: 3 LCDs, 2 lines of 16 characters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Woodward ProTech\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –25 to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLockable Enclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCPU and MPU Failure Indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKey Lock\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpeed-Sensing Frequency Range\u003c\/strong\u003e: 100 Hz to 32 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±(0.05% x Trip Point in Hz + 2 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverspeed Detection\u003c\/strong\u003e: Three speed-sensing units in a two-out-of-three vote configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTrip Point Frequency Range\u003c\/strong\u003e: 250 Hz to 25 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e: 482.6 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e: 310.4 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e: 142.7 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensitive to\u003c\/strong\u003e: Electromagnetic interference, vibration, moisture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Environment\u003c\/strong\u003e: Adequate ventilation, space for servicing, away from direct sunlight, high-current, or high-voltage devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUser Interface\u003c\/h3\u003e\n\u003cp\u003eEach speed-sensing unit has:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLCD Display\u003c\/strong\u003e: 16-character, 2-line\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Controls\u003c\/strong\u003e: Touchpad, potentiometer, LED indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Output\u003c\/strong\u003e: Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":47336160100594,"sku":"9907-147","price":276.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/9907-147_1.jpg?v=1740626528"},{"product_id":"woodward-8237-1600-protech-gii-overspeed-safety-device","title":"Woodward - 8237-1600 ProTech-GII Overspeed Safety Device","description":"\u003ch3 class=\"\"\u003eOverview\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8237-1600\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: ProTech-GII Overspeed Safety Device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: Woodward\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eElectrical Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e2 High Voltage Inputs OR 1 High Voltage and 1 Low Voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e10A at 115Vac\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e20A at 220Vac\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003ePerformance \u0026amp; Protection\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSpeed Readout\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: 4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eMPU \u0026amp; Acceleration Detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: Monitors overspeed and overacceleration events\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: Modbus compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eEnvironmental Conditions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e–20 to +60 °C at 95% humidity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e–20 to +65 °C at 95% humidity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: IP56, dust and water resistant (installed properly)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eDimensions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: 13 x 17.5 x 6.25 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":47476491223282,"sku":"8237-1600","price":274.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/8237-1600_2.jpg?v=1744701249"},{"product_id":"9905-976-woodward-protech-203-overspeed-protection-system","title":"9905-976 | Woodward ProTech 203 | Overspeed Protection System","description":"\u003ch3 class=\"\"\u003eOverview\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-976\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: ProTech 203 Overspeed Protection System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: Woodward\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eElectrical \u0026amp; Power Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e120 Vac\/dc = 88–132 Vac, 90–150 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e7.25 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eOperational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSpeed Calculation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eThree individual speed calculations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eTwo-out-of-three hardware vote for overspeed detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e40 ms maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eTrip Relay Activation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eActivated if two of three units detect overspeed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eOperator Interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e1 Keypad and Display per Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eConfiguration \u0026amp; Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eTrip Speed Set Point\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e250 rpm minimum, 25,000 rpm maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eMPU Fail Set Point\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e100 rpm minimum, 25,000 rpm maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eEnvironmental Conditions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e–25 to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eDimensions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eW: 482.6 mm x H: 310.4 mm x D:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eSystem Design\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eModular Design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eUnits A, B, and C are identical with independent programming\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eCPU Fail Indication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eIncluded as part of the safety features\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":47476503380210,"sku":"9905-976","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/9905-976.jpg?v=1744689173"},{"product_id":"3500-53-electronic-overspeed-detection-system-bently-nevada","title":"3500\/53 Electronic Overspeed Detection System | Bently Nevada","description":"\u003ch3 class=\"\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003e3500\/53\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada \u003c\/strong\u003eElectronic Overspeed Detection System\u003cspan\u003e \u003c\/span\u003ethat monitors overspeed conditions using proximity probes or magnetic pickups.\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSignal \u0026amp; Power\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eAccepts a single transducer signal from a proximity probe transducer or magnetic pickup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eSignal range: +10.0 V to -24.0 V (exceeding this range is internally limited).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e20 kΩ.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e8.0 watts typical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eTransducers\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eBently Nevada 3300 8 mm Proximitor, 3300 16 mm HTPS, 7200 (5 mm, 8 mm, 11 mm, 14 mm), 3300 RAM Proximitor, or Magnetic pickups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eStatus Indicators\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e: Indicates when the 3500\/53 Module is operating properly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eTX\/XR LED\u003c\/strong\u003e: Indicates communication with other modules in the 3500 rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eBypass LED\u003c\/strong\u003e: Indicates when the 3500\/53 is in Bypass Mode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eTest Mode LED\u003c\/strong\u003e: Indicates when the 3500\/53 is in Test Mode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eAlarm LEDs\u003c\/strong\u003e: Indicates an alarm condition with the associated relay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47485636772082,"sku":"3500\/53","price":296.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/350053_1.jpg?v=1744952351"},{"product_id":"ds200tceag1bsf-general-electric-mark-v-emergency-overspeed-board","title":"DS200TCEAG1BSF General Electric Mark V Emergency Overspeed Board","description":"\u003ch3\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eDS200TCEAG1BSF\u003c\/strong\u003e is an Emergency Overspeed Board used in General Electric's Speedtronic Mark V system to monitor and manage overspeed and flame detection trip conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003eMicroprocessor \u003c\/span\u003e\u003cspan\u003e\u0026amp; \u003c\/span\u003e\u003cspan\u003eMemory \u003c\/span\u003e\u003cspan\u003eModules\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe board houses a \u003cstrong\u003esingle microprocessor\u003c\/strong\u003e and \u003cstrong\u003emultiple programmable read-only memory (PROM) modules\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThese components ensure \u003cstrong\u003eprecise system monitoring and response\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003eKey \u003c\/span\u003e\u003cspan\u003eComponents\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThree fuses\u003c\/strong\u003e for circuit protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e30 jumpers\u003c\/strong\u003e allowing configuration adjustments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTwo bayonet connectors\u003c\/strong\u003e for secure connections to the rest of the drive’s components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003eBayonet \u003c\/span\u003e\u003cspan\u003eConnector \u003c\/span\u003e\u003cspan\u003eHandling\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e: Align the connector and press it into place until it clicks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRemoval\u003c\/strong\u003e: Hold both the connector and board to prevent damage, then detach the connector.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":47552353108210,"sku":"DS200TCEAG1BSF","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/DS200TCEAG1BSF__3.jpg?v=1746764481"},{"product_id":"protech-203-unit-8200-205-woodward-digital-overspeed-protection","title":"ProTech 203 Unit 8200-205 Woodward Digital Overspeed Protection","description":"\u003ch3 class=\"\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003e8200-205\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital overspeed protection device from Woodward's ProTech 203 series, featuring a 220 Vac power supply, triple-redundant MPU monitoring, and a lockable enclosure with IP54 protection.\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eGeneral Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Woodward\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: ProTech 203\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 8200-205\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Digital Overspeed Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eProtection Logic\u003c\/strong\u003e: Two-out-of-three trip voting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eDisplay Interface\u003c\/strong\u003e: 1 keypad\/display per module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e: IP54\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 220 Vac\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eTrip Logic\u003c\/strong\u003e: De-energize-to-trip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eEnvironmental Conditions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eDisplay Operating Temperature\u003c\/strong\u003e: +5 to +140 °F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eFrequency and Control\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eTrip-Point Frequency Range\u003c\/strong\u003e: 250 Hz to 25 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSubsystem Access\u003c\/strong\u003e: Lockable PROGRAM\/MONITOR switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eStart Methods\u003c\/strong\u003e: Separate start\/reset or combined start\/reset\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eDimensions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e: 19 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e: 12.244 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e: 5.62 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":47558864240882,"sku":"8200-205","price":298.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/8200-205.jpg?v=1747031013"},{"product_id":"woodward-8237-1369-overspeed-detection-device","title":"Woodward - 8237-1369 | Overspeed Detection Device","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWoodward 8237-1369\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoverspeed detection device\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e, engineered for safe turbine shutdown in hydro, steam, or gas turbine systems.\u003c\/p\u003e\n\u003ch3\u003eElectrical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 24 VDC (low), 115\/240 VAC or 125 VDC (high)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –20 to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: –20 to +65 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: Up to 95% (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Compliance\u003c\/strong\u003e: EN61000-6-4 (emissions), EN61000-6-2 (immunity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e: IP56 (when properly installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSize\u003c\/strong\u003e: 330 × 445 × 159 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e: Triple modular (A\/B\/C modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e: 2-out-of-3 voted logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e: Modbus protocol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e: 4–20 mA speed signals, MPU detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: 15-key keypad per module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e: Reverse polarity for DC, conformal coating for gas resistance (H₂S, SO₂)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot Swappable\u003c\/strong\u003e: Individual modules can be replaced while powered\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":47719537213682,"sku":"8237-1369","price":1200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/8237-1369.jpg?v=1751608506"},{"product_id":"mark-v-ds200tceag1b-ge-emergency-overspeed-board","title":"Mark V DS200TCEAG1B | GE Emergency Overspeed Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDS200TCEAG1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Emergency Overspeed Board from GE Mark V Series, designed to monitor overspeed and flame trip conditions and safely shut down the drive.\u003c\/p\u003e\n\u003ch3\u003eCore Components\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMicroprocessor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple PROM modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuses:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumpers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBayonet type for interfacing with other boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Functions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine overspeed monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlame detection trip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic synchronizing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnectivity\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJ7:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePD Core Power Distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJK:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTCEB Board Signal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJL:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTCTG Board Trip Signal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJW:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTCEB Flame Detection Signal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJX1 \u0026amp; JX2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDaisy-chained IONET connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCircuit Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTCEA Flame Detection Circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTCEA Turbine Overspeed Circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTCEA Automatic Synchronizing Circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48064188514546,"sku":"DS200TCEAG1B","price":490.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/DS200TCEAG1B__2.jpg?v=1761116798"},{"product_id":"emerson-epro-a6370-overspeed-protection-monitor","title":"Emerson Epro A6370 Overspeed Protection Monitor","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eA6370\u003c\/strong\u003e is an overspeed protection monitor from Emerson Epro designed to interface with various sensor types and provide reliable speed monitoring and protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSensor Voltage Supply\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Supply Voltage\u003c\/strong\u003e: -24.5 V ±1.5 V DC, short-circuit proof, galvanically separated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMax. Current\u003c\/strong\u003e: 35 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSignal Input – Eddy Current \u0026amp; Hall Element Sensors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Voltage Range\u003c\/strong\u003e: 0 V to 26 V (±), protected against reverse polarity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLimit Range\u003c\/strong\u003e: ±48 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: 0 to 20 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e: Typical 100 kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSignal Input – Magnetic (VR) Sensors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Voltage Range\u003c\/strong\u003e: Min. 1 Vpp, max. 30 V RMS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: 0 to 20 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e: Typical 18 kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDigital Input (Backplane)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e: 4, galvanically separated with common ground\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTest Value 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTest Value 2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnable Test Values\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReset Latch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLogic Low Level\u003c\/strong\u003e: 0 V to 5 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLogic High Level\u003c\/strong\u003e: 13 V to 31 V, open\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e: Typical 6.8 kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCurrent Output (Backplane)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e: 2, electrically isolated with common ground\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRange\u003c\/strong\u003e: 0\/4 to 20 mA or 20 to 4\/0 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±1% of full scale\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Load\u003c\/strong\u003e: \u0026lt;500 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e: 20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Epro","offers":[{"title":"Default Title","offer_id":48109935427826,"sku":"A6370","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/A6370.jpg?v=1762162208"},{"product_id":"woodward-9907-345-electronic-overspeed-trip-device","title":"Woodward 9907-345 Electronic Overspeed Trip Device","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e9907-345\u003c\/strong\u003e is a Woodward ProTech 203 electronic overspeed trip device with three magnetic pickups, modular design, and fault-tolerant protection for prime mover applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIdentity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e: 9907-345\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: ProTech 203\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Electronic Overspeed Trip Device\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Woodward\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: De-energize-to-Trip\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSize\u003c\/strong\u003e: W 19 in × H 12.244 in × D 5.62 in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 24 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –25 to +60 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpeed-Sensing Frequency Range\u003c\/strong\u003e: 100 Hz–32 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMPU Timeout Range\u003c\/strong\u003e: 100–25,000 rpm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCPU Indication\u003c\/strong\u003e: Failure detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e: Hot replacement, self-test, remote reset, multiple alarm outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e: Three independent MPU units (A, B, C) with two-voter relays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e: Separate operator interface and 24 V DC supply per unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e: Visual and audible, LCD\/LED error messages\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e: NEMA 4 \/ 4X enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48267461034226,"sku":"9907-345","price":436.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/9907-345_1.jpg?v=1764136898"},{"product_id":"8237-1597-woodward-overspeed-protection-device","title":"8237-1597 Woodward Overspeed Protection Device","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e8237-1597\u003c\/strong\u003e is a Woodward ProTech-GII bulkhead mounted overspeed protection device for turbines, engines, and process equipment, featuring modular design, dual voltage inputs, and advanced fault-tolerant architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIdentity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e: 8237-1597\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: ProTech-GII\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Overspeed Protection Device\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSize\u003c\/strong\u003e: H 13 in × W 19.1 in × D 6 in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e: IP56 (IEC 60529)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –4 to +140 °F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: –4 to +158 °F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh Voltage Input\u003c\/strong\u003e: 100–150 V DC @ 30 W\/module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLow Voltage Input\u003c\/strong\u003e: 18–32 V DC @ 30 W\/module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e: 3 internal modules, 3 independent relays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKeypad\/Display\u003c\/strong\u003e: Three 4.2 in displays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e: Two-out-of-three voted design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpeed Readouts\u003c\/strong\u003e: 4–20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDetection\u003c\/strong\u003e: MPU and acceleration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e: Resistant to sulfur contamination (conformal coating)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Suitable for class 3C2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntegration\u003c\/strong\u003e: Easy adaptation to any turbine size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48267592827122,"sku":"8237-1597","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/8237-1597-1.jpg?v=1764136897"},{"product_id":"8237-1246-woodward-overspeed-safety-device","title":"8237-1246 Woodward Overspeed Safety Device","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e8237-1246\u003c\/strong\u003e is a Woodward ProTech-GII overspeed safety device for hydro, steam, and gas turbines, with triple modular design and MPU detection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 330 × 486 × 153 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure type\u003c\/strong\u003e: IP56\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e: Vibration resistance 0.04 G²\/Hz, 1.04 Grms, 10–500 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh voltage input\u003c\/strong\u003e: 90–264 Vac \/ 47–63 Hz or 100–150 Vdc @ 30 W per module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKeypad\/Display\u003c\/strong\u003e: 4.2 in (3 displays)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal high output voltage\u003c\/strong\u003e: 115 Vac \/ 240 Vac \/ 125 Vdc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal low output voltage\u003c\/strong\u003e: 24 Vdc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: –4 to +140 °F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e: –4 to +158 °F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGas resistance\u003c\/strong\u003e: Sulfur, H₂S, SO₂\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctional Design\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTrip relay outputs\u003c\/strong\u003e: 3 independent, non-voted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpeed readouts\u003c\/strong\u003e: 4–20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower input\u003c\/strong\u003e: Low voltage and high voltage supported\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e: 2 out of 3 voted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48401250484466,"sku":"8237-1246","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/8237-1246.jpg?v=1764656530"},{"product_id":"8237-2600-woodward-protech-gii-overspeed-protection-device","title":"8237-2600 | Woodward - ProTech-GII Overspeed Protection Device","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eWoodward 8237-2600 ProTech-GII\u003c\/strong\u003e is an overspeed protection device designed for turbine applications. It provides panel‑mount installation, supports both high‑ and low‑voltage operation, and uses voted relay outputs to ensure reliable trip functionality in safety‑critical environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIdentification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Woodward\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e ProTech‑GII\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 8237-2600\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel mount\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e HV\/LV operation supported\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay Outputs:\u003c\/strong\u003e Voted relays for overspeed trip reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48594682380530,"sku":"8237-2600","price":570.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/8237-2600.jpg?v=1766395059"},{"product_id":"general-electric-ds200tceag1a-emergency-overspeed-board","title":"General Electric DS200TCEAG1A Emergency Overspeed Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS200TCEAG1A\u003c\/strong\u003e is a GE Mark V Emergency Overspeed Board (Protective Processor) that safeguards the turbine using high‑speed protection circuitry, processes signals for synchronization, flame detection, and shaft speed, and interfaces with the STCA and TCTG boards.\u003c\/p\u003e\n\n\u003ch3\u003eKey Functions\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eScaled and conditioned signals written to the STCA board over IONET\u003c\/li\u003e\n  \u003cli\u003eSends emergency trip signals to the TCTG (Turbine Trip Board)\u003c\/li\u003e\n  \u003cli\u003eRelay voting system for trip decisions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConnectors\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJ7:\u003c\/strong\u003e TCEA Board Power Connector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJK:\u003c\/strong\u003e TCEB Board Signals Connector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJL:\u003c\/strong\u003e TCTG Board Trip Signals Connector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJW:\u003c\/strong\u003e TCEB Board Flame Detection Signals Connector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJX1 \/ JX2:\u003c\/strong\u003e Daisy Chained IONET Signal Connectors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":49917957472498,"sku":"DS200TCEAG1A","price":663.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/DS200TCEAG1A.jpg?v=1786610623"}],"url":"https:\/\/www.petrospare.com\/collections\/overspeed-detection.oembed?page=3","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}